2.  IntroductIon

High powered, lightweight industrial units. stainless steel drum with dual 

filtration system for superior performance. Features safety shut-off for wet 

operation. trolleys with swivel bin and two rear locking wheels for easy 
emptying plus front swivel castors for added maneuverability. foot operation 
for squeegee adjustment. supplied with Ø38mm accessory kit, 3.2mtr cable 

with 3 pin plug, cloth and cartridge filters. PC477 is fitted with twin motors 

offering superior vacuuming power to collect any type of solid from dust to 
rubble and is particularly suitable for industrial and commercial applications 
where extra capacity and power are required to clean large areas or large 
volumes of waste. Pc455 features blower facility. optional front mounting 

squeegee available, as illustrated in fig.9.

3.  sPecIfIcatIon

model no.............................................................................Pc477 
motor Power........................................................................2400W 
supply....................................................................................230V 
Air flow............................................................................174m³/hr 
drum size...............................................................................77ltr 
Weight....................................................................................39kg 
Vacuum Accessories Ø........................................................38mm 
filter type...................................................................Paper, cloth 
replacement Paper filter...............................................Pc477.Pf 
replacement cloth filter Basket....................................Pc477.cf 

optional squeegee......................................................Pc477aK1 

overall squeegee length....................................................670mm

4.  assembly

4.1. 

  

Hose Installation. fig. 1.

4.1.1. 

  

fully insert the hose into the suction coupler on the main drum.

 

it will automatically snap into place. 

4.1.2. 

  

to release the hose, slide the release knob in the direction of the

  

arrow and pull the hose out of the suction coupler. 

4.2. 

  

filter removal. fig. 2a/2b 

4.2.1. 

  

To access the filter, unclip and remove the upper part of the 

4.2.2. 

  

cleaner from the metal tank.

4.2.3. 

  

To change the paper cartridge filter push the retaining clip in the

  

direction of the arrow (fig.2b) and remove the filter from the motor 

 unit. 

4.2.4. 

  

For wet vacuuming remove the paper cartridge filter and install 

 

the fabric filter over the filter basket. The filter basket (fig.2a) sits

  

in the top of the drum and is held in place when the upper part of

  

the vacuum cleaner is clipped onto the tank. 

4.3. 

  

locking and unlocking the tank. fig. 4.

4.3.1. 

  

lock the tank to the frame support by pushing the knobs doWn.

4.3.2. 

  

unlock the tank from the frame support by pushing the knobs uP.

4.3.3. 

  

When the tank is unlocked it can be lifted from the frame.

4.3.4. 

  

the tank must only be tipped for emptying in the locked position. 

 

fig.13.

5.  oPeratIon

5.1.    

nozzles

5.1.1. 

  

The brush nozzle is used on large, dry areas such as a floor 

 

or a bed. fig. 5.

5.1.2.   

the squeegee nozzle is used on water, cement or other 

 non-volatile 

substances. fig. 6.

5.1.3.    the round brush is used on small areas such as a sofa, window

  

or the 

corner of a floor. Fig. 7.

5.1.4.   

the crevice tool is used on narrow grooves or windows. fig. 8.

   fig.1

   fig.2a

   fig.2b

   fig.4

   fig.5

   fig.6

   fig.7

   fig.8

Pc477,Pc477AK1.V2 | issue 4 05/12/16

Original Language Version

© Jack sealey limited

Summary of Contents for PC477

Page 1: ...fuse see fuse rating 8 8 DO NOT pull or carry the appliance by the power cable 8 8 DO NOT pull the plug from the socket by the cable 8 8 DO NOT use worn or damaged cables plugs or connectors Immediately have any faulty item repaired or replaced by a qualified electrician When an ASTA BS approved UK 3 pin plug is damaged cut the cable just above the plug and dispose of the plug safely Fit a new plu...

Page 2: ... 1 Fully insert the hose into the suction coupler on the main drum It will automatically snap into place 4 1 2 To release the hose slide the release knob in the direction of the arrow and pull the hose out of the suction coupler 4 2 Filter Removal Fig 2a 2b 4 2 1 To access the filter unclip and remove the upper part of the 4 2 2 cleaner from the metal tank 4 2 3 To change the paper cartridge filte...

Page 3: ...t by hand patting the filter 6 1 1 Remove the vacuum cleaner head to access the filter Fig 12 6 1 2 Remove all dust on the filter Clean and if necessary air dry the filter for further use 6 2 Emptying the Tank 6 2 1 Position the cleaner next to a suitable container or drain Lock tank onto frame Fig 4 Put the rear wheel locks on Hold the frame handle with one hand and lift the tank to the emptying ...

Page 4: ...ntre and disposed of in a manner which is compatible with the environment When the product becomes completely unserviceable and requires disposal drain off any fluids if applicable into approved containers and dispose of the product and the fluids according to local regulations WEEE Regulations Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Elec...

Reviews: