LED045, LED046 issue: 1 - 02/04/14
Mounted in die-cast aluminium housing with wall mounting pre-drilled holes. features 4 high power Epistar™ LEDs mounted in swivel head(s).
supplied without mains cable and suitable for outdoor mounting.
Model No: . . . . . . . . . . led045 . . . . . . . . . . . . . . . . . . led046
Power . . . . . . . . . . . . . . . . .10W . . . . . . . . . . . . . . . . . . . . . 20W
Lumen output . . . . . . . . . 720lm . . . . . . . . . . . . . . . . . . .1440lm
supply. . . . . . . . . . . . . . . . 230V . . . . . . . . . . . . . . . . . . . . 230V
3.1.3. this LED floodlight develops minimal heat and is not subject to the same mounting restrictions that apply to halogen lamps that become
too hot to touch. We do however recommend that the floodlight should not be placed in cramped or restrictive positions and should be
fixed at the following minimum distances between the light and any surface/object. see fig.3.
● 500mm minimum between the top of the light and any overhead surface, or objects, i.e. ceilings, overhangs.
● 200mm between sides of light and end or side walls, surface or objects.
● 2 metres minimum between the front of the light and any object to be illuminated.
3.1.4. fix the light to vertical surface with appropriately strong screws or bolts.
3.1.5. Ensure the unit is connected to the electrical supply by a qualified electrician in accordance with the wiring
instructions in section 1.1.9.
3.2. geNeral
● Clean the light with a dry, dust-free cloth.
●
do Not
use solvents, or abrasives to clean the light.
● Avoid touching the glass shield (as handling may reduce its serviceable life and cause the glass to crack. If
necessary clean the shield with alcohol and a soft cloth.
●
do Not
use the light without the glass shield.
●
do Not
use the light without the weather seals intact.
3.3. light soUrce
the LED light source is designed to last the lifetime of the product and is not a user servicable item. in the event of light source failure
the product should be returned to you local sealey dealer for servicing.
3.1. iNstallatioN.
p
warNiNg! ensure the unit is not connected to the mains power supply before installation.
3.1.1. consider the position of unit to ensure you obtain maximum benefit from the lighting, and that an appropriate electrical power source
can be provided.
3.1.2. the light must be mounted vertically only i.e. on a wall etc.
do Not
mount horizontally i.e.ceiling or overhang,
do Not
mount so that
the face of the lamp is pointing upwards, or is facing towards the mounting surface.
fig.3
Parts support is available for this product. to obtain a parts listing and/or diagram, please log on to
www.sealey.co.uk, email [email protected] or phone 01284 757500.
2. iNtrodUctioN
3. sPecificatioN
3. iNstallatioN
noTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMPortaNt:
no liability is accepted for incorrect use of this product.
warraNtY:
Guarantee is 12 months from purchase date, proof of which will be required for any claim.
iNforMatioN:
for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
sole Uk distributor, sealey group,
Kempson Way, suffolk Business Park
,
Bury st. Edmunds, suffolk,
iP32 7Ar
www.sealey.co.uk
Original Language Version
© Jack sealey Limited
environmental Protection
recycle unwanted materials instead of disposing of them as waste. all tools, accessories and packaging should be
sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.
weee regulations
dispose of this product at the end of its working life in compliance with the eU directive on
waste electrical and electronic equipment (weee). when the product is no longer required, it must be disposed
of in an environmentally protective way. contact your local solid waste authority for recycling information.