background image

3.1. 

Fit The Handle (FIG.1).

3.1.1.  The IR1000 has been packed with a separate handle and lamp 

ready for attachment and fitting to the heater. Please leave the 

lamp in transit packing until ready to fit.

3.1.2.  The handle should be attached to the main unit by means of the 

bolt supplied, ensuring the spacer provided is fitted between the 

two fixing posts of the heater. Please ensure the washer is 

fitted under the nut, then fully tighten to secure.

3.1.3.  When fitted, the pre-made hole in the grip of the handle should be 

at the bottom of the heater. If correct you will be able to tilt the 

body of the heater in a downward direction only.

3.2 

Fit The Lamp (FIG.1).

3.2.1.  Remove the two screws (17) from one end reflector  (2), this will 

release the guard (3) and expose one of the lamp terminal end 

posts (18).  

3.2.2.  Now remove the other end reflector (2) exposing the other lamp 

terminal (18). 

3.2.3.  Release the nuts (12) on the exposed terminal end posts just 

enough to allow the fork terminals of the lamp leads to be pushed 

under the washers (13). 

3.2.4.  Carefully remove the lamp (19) from its packing, holding it by the 

porcelain end caps only, taking care not to handle the quartz 

 glass.

3.2.5.  Carefully insert the end caps of the lamp under the spring 

retaining clips (7 & 8) of the heater. The fork terminals on each  

end of the lamp should now be inserted under the washer (13) of 

the lamp end posts and nuts (12) tightened to make a good 

 connection.

3.2.6.  The lamp leads should then be tucked away around the space at 

each end of the heater.

3.2.7.  Now replace the end reflectors (2) and guard (3) to complete the 

 assembly.

Fig.1

Material  

Drying Time 

Distance

Polyester stopper 

08 - 12mins 

600 - 700mm

MS primer 

15 - 18mins 

500 - 600mm

Water-based filler paint 

15 - 18mins 

500 - 600mm

Finishing paint 

18 - 25mins 

400 - 500mm

4.4

 

ON/OFF

 switch. To switch the unit on operate the rocker switch on the

underside of the unit. The ‘O’ symbol is the ‘OFF’ position and the ‘I’ 

symbol is the ‘ON’ position. 

Important: Excessive drying time will burn the paint and may distort the

 panel.

4.5.

 

When the heating period is over switch off at socket and then remove dryer 

 plug.

4.6.

 

Allow the dryer to cool before moving it to a safe, dry, childproof storage area.

5. ASSEMBLY

6. OPERATION

Environmental Protection

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, 

taken to a recycling centre and disposed of in a manner which is compatible with the environment.

When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)

into approved containers and dispose of the product and the fluids according to local regulations.

WEEE Regulations

Dispose of this product at the end of its working life in compliance with the EU Directive on 

Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed

of in an environmentally protective way. Contact your local solid waste authority for recycling information.

Note:  The IR lamp is fragile and therefore it is important that the IR1000 is not subjected to any unnecessary shocks or vibration and 

is not moved when the lamp is on.

 

WARNING! Ensure that you read, understand and apply the safety instructions in Section 1 before using the panel dryer.

4.1. 

Allow a 4-5 minute 'flash-off' period for excess solvent to evaporate before close positioning of dryer to panel - solvent boil or popping may occur

if the panel temperature is raised too rapidly. Remove or otherwise protect, any trim items on or adjacent to the panel to prevent possible 

 distortion.

4.2. 

Position the lamp approximately 500mm from the panel. 

4.3. 

Paint to lamp distance and heating time are dependant on a number of factors including the paint type and workshop conditions and are best 

based on experience. However rough guidelines are as follows:

Reviews: