ELECTRICAL SAFETY

  

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other  

connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. 

A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current 

Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an 

RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1. The 

Electricity at Work Act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified  

 

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances  

 

and the safety of the appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and  

 

 

1.1.2. and use a Portable Appliance Tester.

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply cables and plugs for wear or damage and check all connections

 

to ensure that none are loose.

1.1.6. 

Important:

 Ensure that the voltage marked on the appliance matches the power supply to be used

 

and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT 

pull the plug from the socket by the cable.

1.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When an ASTA/BS approved UK 3 pin plug

 

is damaged, cut the cable just above the plug and 

dispose of the plug safely. 

 

Fit a new plug according to the following instructions (UK only).

 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b)  Connect the BROWN live wire to the live terminal ‘L’.

 

c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d)  After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation  

 

extends beyond the cable restraint and that the restraint is tight.

 

Double insulated products, which are always marked with this symbol      , are fitted with live (brown) and neutral (blue) wires only.     

 

To rewire, connect the wires as indicated above - 

DO NOT

 connect either wire to the earth terminal.

1.1.10.  If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance    

 

plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the  

 

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of  

 

2.5mm² section cable.  

1.2.   GENERAL SAFETY INSTRUCTIONS

  

WARNING! If a fuse blows, ensure it is replaced with a fuse of identical type and rating.

  

WARNING! Ensure there is nobody in front of the lamp when it is switched on.

 

Disconnect the panel dryer from the power supply before servicing, changing accessories, or performing any maintenance.

  Ensure that the panel dryer is in good condition before use. If in any doubt do not use the unit and contact an electrician.

  When not in use, store the panel dryer carefully in a safe, dry, childproof location.

  Familiarise yourself with the application and limitations of the panel dryer.     

  Check that lamp guards are in place, undamaged and firmly attached. 

  Keep tools and other items away from the panel dryer when it is in use.

  Keep the work area clean and clear of unnecessary items.

  Keep children and unauthorised persons away from the work area.

 

Remember that the lamp panel will get hot, allow to cool after use.

 

 

Maintain the panel dryer in good condition. Use authorised agent for servicing. 

 

Keep the dryer clean, but 

DO NOT

 use solvents.

 

Use only genuine parts and accessories. 

Unauthorised parts and accessories may be dangerous and will invalidate your warranty.

 

DO NOT

 use this product to perform a task for which it has not been designed.

 

DO NOT

 use the panel dryer outdoors, or in damp, or wet locations, and 

DO NOT

 operate within the vicinity of flammable liquids, gases or  

 solids.

The IR1000 has been designed and developed to assist with any number of small drying processes, and is ideal for spot repairs, engine drying, 

adhesive stripe removal, drying filler, primer or just preheating prior to spraying.

It may be used as a stand alone system, when fitted to the slide and lock bracket on the separately available lightweight stand IR1000ST, or as a 

source of instant direct heat, when used as a handheld. Fitted with a powerful 1kW short wave infrared lamp - instant heat can be directed 

wherever and whenever it may be required.

Original Language Version

IR1000    Issue: 3(L) - 09/06/14

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE 

PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 

PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

RECOMMENDED

 FUSE RATING: 13AMP

 1.  SAFETY

 2.  INTRODUCTION

 © Jack Sealey Limited

Reviews: