background image

 

9

   use recommended parts only. unapproved parts may be dangerous, and will invalidate your warranty.

 

8

  

do not

 operate the fan where there are explosive or flammable gases, fumes or other hazardous substances.

 

8

  

do not

 stand the fan on the power cable. 

 

8

  

do not

 insert any objects through the fan guard.

 

8

  

do not

 cover the fan when in use.

 

8

  

do not

 immerse the fan in water or any other liquid.

 

8

  

do not

 allow children to operate the fan.

 

8

  

do not

 stand the fan where it may be knocked over or off a surface, or where the lead may cause a person to trip.

 

8

  

do not

 modify speed control or attempt to fit any additional external speed control device to the fan.

 

9

   When not in use place the fan in its original box, or cover, to protect from dust and store in a safe, dry, childproof location.

 

note: this appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental 

 

capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the  

 

         

appliance in a safe way and understand the hazards involved. children shall not play with the appliance. cleaning and user    

 

 

maintenance shall not be made by children without supervision.

2.  introduction

High velocity fans suitable for movement of huge volumes of air. robust unit with heavy duty gauge steel casing, guard and frame. featuring a 

360° tilt function allowing for the direction of air flow to be positioned anywhere on a 360° axis. carefully balanced and fully guarded blades 

provide quiet and safe operation. fitted with Bs fully approved plug. suitable for use in industrial, commercial, agricultural, automotive 

workshop and showroom applications.

3.  sPecification

Model no.

 .........................................

hvf20s

 ............................

hvf24s

fan diameter ..............................550mm (20”) .....................610mm (24”)

speeds ......................................................... 3 ....................................... 2

speed range ........................1,150-1,350rpm ..................1300-1400rpm

maximum Airflow ........120mtr³/min (4300cfm) .....210mtr³/min (7400cfm)

motor Power ...................................100-170W .........................190-250W

supply.....................................................230V .................................230V

current..................................................... 0.5A .................................. 1.1A

4.  oPeration

 

‰

  

Warning! 

ensure that you read, understand and apply safety instructions in section 1 before using fan.

4.1.    

check that the speed control is set to “0” (off) and then plug into the mains power supply and switch the power on.

4.2.    

the fan features 2 speeds (HVf24s) or 3 speeds (HVf20s) which are selectable using the switch located on the back of the fan.

4.3.    

Adjust the direction of the air flow by rotating and tilting the fan up or down as required.

3.4. 

When you have finished using the fan ensure you turn the speed control switch to “0” (off) , disconnect the fan from the power supply.

4.4.    

Wall mounting (HVf20s only) using the supplied fixing kit.

4.4.1.   

the fan hangs from the base support (5) on the parts diagram, using the three hanging brackets.

4.4.2.   

select the appropriate fixing from those supplied, and space the three hanging brackets equally along the base support. Hang the fan  

 

and fit the set screws through the brackets to secure the fan. 

5.  Maintenance

 

‰

 

  Warning! 

ensure that the fan is disconnected from the mains power supply before attempting any of the following:

5.1.    

use a soft, damp cloth to clean the fan.

 do not

 immerse the fan in water and never allow water to drip onto the motor housing. 

do  

 

not

 use solvents, petroleum, paint thinner or other chemicals to clean the fan.

5.2.    

to clean the fan blade, undo the cross headed screws around the circumference, remove the grille and clean the blade with a slightly  

 

damp cloth. replace the grille as required and refit the cross headed screws.

5.3.    

should the motor, switch or the power lead require service or maintenance contact your local sealey service agent.

5.4.    

When not in use place the fan in its original box or otherwise cover to protect from dust, and store in a safe, dry, childproof location.

NOTE: 

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

iMPortant:

 no liability is accepted for incorrect use of this product.

Warranty:

 Guarantee is 12 months from purchase date, proof of which will be required for any claim.

sole uK distributor, sealey Group.

Kempson Way, suffolk Business Park,

Bury st. edmunds, suffolk.

iP32 7Ar

www.sealey.co.uk

[email protected]

01284 757500

01284 703534

environmental Protection

recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be 

sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.

When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)

into approved containers and dispose of the product and the fluids according to local regulations.

Weee regulations

dispose of this product at the end of its working life in compliance with the eu directive on 

Waste electrical and electronic equipment (Weee). When the product is no longer required, it must be disposed

of in an environmentally protective way. contact your local solid waste authority for recycling information.

Parts support is available for this product. to obtain a parts listing and/or diagram, 

please log on to www.sealey.co.uk, email [email protected] or telephone 01284 757500.