background image

8.3.  Assemble the roof panel.

8.3.1.  Place two 8 sheetings on the work table and join together with the self tapping screws as per the  

 diagram.

8.3.2.  Now tap or slide in 20A and 20A channels to the sheeting and fix them using the self tapping    

 screws.

8.3.3.  Now fit two 51 side lips to the sheeting and fix them using

 the self tapping screws.

Original Language Version

GSS1515G    Issue: 1 - 26/09/14

 © Jack Sealey Limited

Summary of Contents for GSS1515G

Page 1: ...WARNINGS CAUTIONS USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED FAILURE TO DO SO MAY CAUSE DAMAGE AND OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE Thank you for purchasing a Sealey product Manufactured to a high standard this product will if used according to these instructions and properly maintained give you ye...

Page 2: ...u use builders plastic and F52 reinforcing mesh We recommend that you make the slab 100mm bigger than the base dimensions of the shed This will allow for a 50mm edge around the shed We recommend that you slope the 50mm edges downward by 10 mm so that rain water can be drained away from the shed 4 CONCRETE SLAB Original Language Version GSS1515G Issue 1 26 09 14 Jack Sealey Limited ...

Page 3: ... Sheet Sheet 2057x770 zinc left rear wall 6L 1 Sheet Sheet 2057x770 zinc right rear wall 6R 1 Sheet Sheet 1977 2057x770 zinc left side wall 7L 1 Sheet Sheet 1977 2057x770 zinc right side wall 7R 1 5 TOOLS REQUIRED 6 CONTENTS Original Language Version GSS1515G Issue 1 26 09 14 Jack Sealey Limited ...

Page 4: ...zinc rear wall 20C 1 Channel channel 1508 zinc front 20D 1 Channel channel 1508 zinc front 20E 1 Channel channel 1515 zinc side wall 25 2 Channel channel 1898 zinc front 22 1 Channel channel 775 zinc front 23 1 Channel channel 1458 zinc rear wall side wall 31 3 Channel channel 674 zinc front 33R 1 Jamb jamb 1898 white front 41A 1 Jamb jamb 1898 white front 41B 1 Jamb jamb 775 white front 42 1 Lip ...

Page 5: ...er 1 Bracket 8 M8 18m m Hexagonal bolt 8 M8 Hexagonal Nut 8 Mid wall brace bracket 3 Self tapper safety cover 25 Channel safety cover L type 1 Channel safety cover R type 1 Rawl bolt 8 In the unlikely event that you find you are missing a part please contact your Sealey dealer Original Language Version GSS1515G Issue 1 26 09 14 Jack Sealey Limited ...

Page 6: ...7 PARTS DIAGRAM Original Language Version GSS1515G Issue 1 26 09 14 Jack Sealey Limited ...

Page 7: ... sheeting on the work table and join together with the self tapping screws as per the diagram 8 1 2 Now fit 20B top channel and 20C bottom channel to the sheeting by tapping it in diagram A or sliding it in diagram B Note that the small lip of the channel is always facing out This is to ensure that rain water cannot build up inside the shed 8 ASSEMBLY Original Language Version GSS1515G Issue 1 26 ...

Page 8: ...ting and position it using the self tapping screws Please note that the groove should face downwards Position the top and bottom channels using the self tapping screws as well Original Language Version GSS1515G Issue 1 26 09 14 Jack Sealey Limited ...

Page 9: ...el using the self tapping screws Fix 20A the bottom channel with the self tapping screws but not 25 the top channel in this stage Note that the small lip of the channel is always facing out This is to ensure that rain water can not build up inside the shed Repeat the same steps for 2L and 7L the other side wall Original Language Version GSS1515G Issue 1 26 09 14 Jack Sealey Limited ...

Page 10: ...lf tapping screws as per the diagram 8 3 2 Now tap or slide in 20A and 20A channels to the sheeting and fix them using the self tapping screws 8 3 3 Now fit two 51 side lips to the sheeting and fix them using the self tapping screws Original Language Version GSS1515G Issue 1 26 09 14 Jack Sealey Limited ...

Page 11: ...Original Language Version GSS1515G Issue 1 26 09 14 Jack Sealey Limited ...

Page 12: ... aligned and 33R the mid wall channel to the sheeting and fix them using the self tapping screws not those with cross mark at this stage 8 4 2 Fit the 41A jamb 42 jamb and 23 bottom channel in and fix them using the self tapping screws not those with cross mark at this stage Be aware of the joint details as per the diagrams Diagram B is the same as diagram A Original Language Version GSS1515G Issu...

Page 13: ...e front wall panel as per the diagram Use riveter to fix the door into the pre drilled holes Fix 70 pad bolt but NOT its keeper in this stage to the pre drilled holes and rivet or use self tapping screws as required Original Language Version GSS1515G Issue 1 26 09 14 Jack Sealey Limited ...

Page 14: ...ack wall then the front wall then the roof Fix all the components using the self tapping screws Fix 71 pad bolt keeper with rivets or screws as required For greater security fit rivets as below Original Language Version GSS1515G Issue 1 26 09 14 Jack Sealey Limited ...

Page 15: ... 8 6 2 Now fit the bolt down kit as per the diagram Strengthen the mid wall brace by applying 72 the mid wall brace bracket on each corner Original Language Version GSS1515G Issue 1 26 09 14 Jack Sealey Limited ...

Page 16: ...afety cover L type on channel 32 and R type on channel 33R Apply the self tapper covers on the screws fixed on the wall to prevent accidental injuries Original Language Version GSS1515G Issue 1 26 09 14 Jack Sealey Limited ...

Page 17: ...ed on the opposite side Align the door with the edge and drill new holes Remove the pin from the hinge and reverse it before assembling the door Fill the old pre drilled holes with rivets if required Perform the same procedure for the pad lock ...