background image

  5.  STORAGE OF MORE THAN 30 DAYS

Note:  If you store the generator for more than 30 days it is essential to protect the fuel system. This can be done by draining   
 

all the fuel or by adding a fuel additive to prevent fuel gum deposits from forming. 

Note:  Store the generator in a safe, dry, childproof area, free of excessive humidity and dust.

 

WARNING! Petrol is highly flammable and petrol vapour is explosive. Do not permit smoking, naked flames, sparks or heat   

 

in the vicinity while handling petrol. Avoid spilling petrol onto a hot engine. Comply with all laws regulating storage and 

 

handling of fuels.

5.1 

CLEAN

5.1.1 

Remove debris and dust accumulations from the generating set surfaces.

5.2 

DRAINING ALL THE FUEL

5.2.1 

Turn the fuel valve On and siphon the fuel into an approved container.

5.3 

USING A FUEL ADDITIVE

5.3.1 

Fill the fuel tank with fresh fuel. 

Note:  If only partially filled, air in the tank will promote fuel deterioration during storage.

5.3.2 

Add the fuel stabiliser following the manufacturer’s instructions.

5.3.3 

Run the engine outdoors for ten minutes to ensure that all untreated fuel has been used.

5.3.4 

Stop the engine and move the fuel valve to the OFF position.

5.4 

BORE LUBRICATION

5.4.1 

Remove the spark plug and pour approximately 25ml of clean engine oil into the cylinder.

5.4.2 crank the engine several times in order to circulate the the oil into the cylinder, then refit the spark plug.
5.4.3 

Slowly pull the recoil starter cord until some resistance is felt, then keep pulling until the arrow on the starter pulley aligns with the hole  

 

on the recoil starter.

  6. TROUBLESHOOTING

PROBLEM

CAUSE

REMEDY

engine will not start

Fuel tap not turned on

Turn fuel on

no fuel in tank

Fill fuel tank

engine run switch not turned on

Switch to On position

choke not set correctly

Adjust choke position

Spark plug fouled

clean/replace spark plug

Air filter blocked

Clean/replace air filter

engine runs rough

Air filter blocked

Clean/replace air filter

Spark plug fouled

clean/replace spark plug

choke not set correctly

Adjust choke position

Dirty/stale fuel

Drain and replace fuel

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: 

no liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. edmunds, Suffolk,
IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

GG0720    Issue: 2 - 14/10/09

Reviews: