background image

INSTRUCTIONS FOR:

BENCH MOUNTED pillar Drill

MODEL No: 

GDM50B (GDM50BX)

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 

plEaSE rEaD THESE iNSTrUCTiONS CarEFUllY. NOTE THE SaFE OpEraTiONal rEQUirEMENTS, WarNiNGS aND CaUTiONS. 

USE THiS prODUCT COrrECTlY aND WiTH CarE FOr THE pUrpOSE FOr WHiCH iT iS iNTENDED. FailUrE TO DO SO MaY CaUSE 

DaMaGE aND/Or pErSONal iNJUrY, aND Will iNValiDaTE THE WarraNTY. plEaSE KEEp iNSTrUCTiONS SaFE FOr FUTUrE USE.

  1.  SaFETY iNSTrUCTiONS

1.1. 

ElECTriCal SaFETY. 

WarNiNG! it is the user’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and 

all electrical connections for wear or damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety 

devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD

(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD with portable products that are plugged 

into an electrical supply not protected by an RCCB. If in doubt consult a qualified electrician. You may obtain a Residual Current Device by 

contacting your Sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1.  The 

Electricity At Work Act 1989

 requires all portable electrical appliances, if used on business premises, to be tested by 

 

a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2.  The 

Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of those appliances 

 

and the safety of appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure  the  insulation  on  all  cables  and  the  product  itself  is  safe  before  connecting  to  the  mains  power 

supply. 

 

See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply leads and plugs for wear or damage and connections to ensure that none  

 

is loose. 

1.1.6. 

Important:

 

Ensure the voltage marked on the product is the same as the electrical power supply

 

to be used, and check that plugs are fitted with the correct capacity fuse. A 13 amp plug may  

 

require a fuse smaller than 13 amps for certain products (

subject to 1.1.10. below).

 

1.1.7.  DO NOT pull or carry the powered appliance by its power supply lead. 

1.1.8.  DO NOT pull power plugs from sockets by the power cable.

1.1.9.  DO NOT use worn or damage leads, plugs or connections. Immediately replace or have repaired by 

 

a qualified electrician. Where a U.K. 3 pin plug with ASTA/BS approval is fitted, in case of    

 

damage, cut off and fit a new plug according to the following instructions (discard old plug safely).

 

(UK only - see diagram at right). 

Ensure the unit is correctly earthed via a three-pin plug. 

 

a)   Connect the gREEN/YEllOW earth wire to the earth terminal ‘E’.

 

b)  Connect the bROWN live wire to the live terminal ‘l’.

 

c)   Connect the bluE neutral wire to the neutral terminal ‘N’.

 

 

After wiring, check there are no bare wires, that all wires have been correctly 

 

 

connected, that the cable outer insulation extends past the cable restraint and that the cable restraint is tight.

 

 

Double insulated products are often fitted with live (BROWN) and neutral (BLUE) wires only. Double insulated products are always    

 

marked with this symbol      . 

To re-wire, connect the brown & blue wires as indicated above.

 

DO NOT connect the brown or blue  

 

wires to the earth terminal.

1.1.10. 

NOTE: 

If this product requires more than a 13 amp electrical supply, then 

NO

 plug is fitted. 

You must

  therefore contact a qualified    

 

electrician to ensure a 30 amp fused supply is available. We recommend you discuss the installation of a industrial round pin plug and  

 

socket with your electrician. 

1.1.11. 

Cable extension reels

. When a cable extension reel is used it should be fully unwound before connection. A cable reel with an RCD

 

fitted is recommended since any product which is plugged into the cable reel will be protected. The section of the cores in the cable

 

is important and should be at least 1.5mm², but to be absolutely sure that the capacity of the cable reel is suitable for this product and  

 

for others that may be used in the other output sockets, the use of 2.5mm² section is recommended .

Blue 

Neutral 

wire

Yellow & Green 

Earth wire 

Cable 

restraint

rEplaCEMENT FUSES MUST 

BE OF THE SaME TYpE aND 

raTiNG aS THE OriGiNal

Brown

Live 

wire

1.2 

GENEral SaFETY

p

 

WarNiNG! Disconnect drill from mains power before changing accessories, servicing or performing any  

 

  maintenance.

3

 

Maintain the

 

drill in good condition (use an authorised service agent).

p

 

WarNiNG!

 

Keep all guards and holding screws in place, tight and in good working order. Check regularly  

  for damaged parts. a guard, or any other part, that is damaged must be repaired or replaced before the  

  tool is next used, to ensure that it will operate properly and perform its intended function. The safety  

  guard is a mandatory fitting where the drill is used in premises covered by the Health & Safety at Work act. 

3

  Check alignment of moving parts and check for possible broken parts. 

3

  Replace or repair damaged parts. 

Use recommended parts only. Non-authorised parts may be dangerous and  

  will invalidate the warranty.

3

  Ensure the set screws of the head frame are screwed tight before using the drill. 

3

  Secure the drill to a supporting structure to avoid the machine tipping, sliding or walking. Drill is designed for  

  use with drill bits only. No other accessory may be used.

3

  Ensure the chuck is securely fastened to the spindle.

3

  Remove adjusting keys and wrenches from the machine and working area before switching on.

3

  Use clamps or a vice (not included) to secure the workpiece. Available from your Sealey dealer. 

 

DO NOT

 secure  the workpiece by hand. 

3

  Refer to speed chart for recommended drilling speeds.

p

 

WarNiNG! always wear approved eye or face protection when operating this drill. Use a face or dust  

  mask if dust is generated. 

p

 

WarNiNG! DO NOT wear gloves when drilling.

Original Language Version

GDM50B (GDM50BX)    Issue: 3 - 05/03/12

Summary of Contents for GDM50B

Page 1: ...ly see diagram at right Ensure the unit is correctly earthed via a three pin plug a Connect the green yellow earth wire to the earth terminal E b Connect the brown live wire to the live terminal L c Connect the blue neutral wire to the neutral terminal N After wiring check there are no bare wires that all wires have been correctly connected that the cable outer insulation extends past the cable re...

Page 2: ...ol drugs or intoxicating medication 7 DO NOT pull the cable from the power supply 3 When not in use switch the drill off remove plug from the power supply and do not leave until the tool has come to a complete stop 3 TECHNICAL SPECIFICATION 2 DESCRIPTION The GDM50B 5 speed bench drill is suitable for light industrial agricultural and woodworking applications The drill is fitted with a flip up safe...

Page 3: ...depth required Tighten locking screw 6 6 3 When ready to drill simply pull the feed handle The drill will stop at the set depth 6 OPERATING INSTRUCTIONS Note Figures are illustrative and may differ in detail from your drill 5 1 Assembly 5 1 1 Place the column assembly on the base align holes and secure with the four bolts and washers provided 5 1 2 Install the table bracket onto the column togethe...

Page 4: ... 8 3 Periodically lubricate the table elevation rack gear worm mechanism 8 MAINTENANCE 7 DRILL speeds Drill Speed rpm Drill Dia mm Steel Cast Iron Iron Alum Copper 3 1820 2580 2580 2580 4 1350 1820 1820 2580 5 1290 1350 1350 2580 6 970 1290 1290 2580 7 830 970 970 2580 8 830 970 970 2580 9 500 970 830 1820 10 500 830 830 1820 11 500 830 830 1820 12 420 830 500 1820 13 420 500 500 1350 14 420 500 5...

Reviews: