background image

INSTRUCTIONS FOR:

OPTICAL ALIGNMENT GAUGE

Model No: 

GA40

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

GA40  - 1  - 080304

1. SAFETY INSTRUCTIONS

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE

DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.1

GENERAL SAFETY

p

WARNING!

Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.

3

Maintain the gauge in good condition (use an authorised service agent).

3

Replace or repair damaged parts. 

Use genuine parts only. Unathorised parts may be dangerous and will invalidate the warranty.

3

Locate gauge in a suitable working area, keep area clean and tidy and free from unrelated materials. 

p

WARNING! 

Use gauge on level and solid ground.

3

Keep the gauge clean to ensure accurate performance.

7

DO NOT

use outside in damp or wet weather conditions. 

7

DO NOT

allow untrained persons to operate the gauge.

7

DO NOT

leave the gauge unattended.

p

WARNING! 

When setting front end alignment on commercial vehicles never make adjustments to drop arms or interconnecting links. Doing

so could result in serious tyre, wheel and steering problems.

3

Any alignment changes deemed necessary as a result of using this equipment must be made strictly in accordance with the vehicle 

manufacturer’s recommendations.

2. INTRODUCTION & SPECIFICATION

Steel and cast aluminium construction. 

Measures toe-in and toe-out by contact with wheel rims and using optical sight to align markers. 

Works on practically all cars and light commercial vehicles with rim diameters between 200mm and 600mm. 

3.1. ASSEMBLY.

Your gauge has been supplied in flat pack form for quick and easy assembly. 

3.1.1 Take each ready assembled side frame in turn and slide on the balance leg (fig.1.8). Slide the balance leg back onto the alignment peg 

and tighten the thumbscrew.

3.1.2 Place the two frames opposite each other with each extended bar portion positioned to the right hand side. The frame nearest to you is 

the one to which the periscope (fig. 1.3.) unit should be attached. 

3.1.3 Place the periscope unit onto the tube and slide it to the left until it stops against the end of the tube. Tighten the two thumb screws on 

the back of the unit to secure it to the main bar. Attach the target plate (fig. 1.4.) to the periscope using the screws supplied.

3.1.4 Slip the mirror unit (fig. 1.2.) onto the main bar of the other frame and tighten the thumb screw to secure it.
3.1.5 Attach a contact bar (fig. 1.1.) to each of the upright arms. Firstly loosen the thumb screw on the contact bar holder and place through 

the upright arm. Slide the square portion of a contact bar through the holder, tighten the thumbscrew to secure.

3.1.6 Each contact bar may be fitted either to the left or the right of its respective support arm. This is to allow the gauge to handle all tyres 

on 8” to 24” diameter rims and to allow close contact when required e.g. when in use on a vehicle lift.

3.2. CALIBRATION. 

The gauge will be calibrated each time it is used as part of the process of checking wheel alignment. Calibration will be

done with the two halves of the gauge facing each other with the contact bars touching. 

3. ASSEMBLY & CALIBRATION

Fig. 1.

Fig. 2.

Reviews: