  8.  TROubLESHOOTING

  9.  TRaNSPORT  & STORaGE

Problem

Cause

Remedy

Engine will not start

Insufficient fuel

Check and refill fuel tank

Fuel / Ignition switch in 'OFF' position

Switch to 'ON'

Engine oil is low

Check and top up oil

Spark plug fouled

Clean or replace spark plug

Incorrect starting technique

Read section 5 for correct technique

No power generated Circuit breaker in 'OFF'  position

Reset to 'ON'

9.1. 

Always transport and store the generator in an upright position.

9.2. 

Ensure that the fuel switch and ignition switch are placed in the 'OFF' position.

9.3. 

When the engine has cooled, turn the fuel cap breather to the 'OFF' position to avoid the risk of fuel spillage.

9.4.

 

When not in use, store the generator in a cool, dry location out of the reach of children and away from sources of ignition.

9.5. 

If being stored for a long period, drain the fuel tank.

Parts support is available for this product. To obtain a parts listing and/or diagram, 

please log on to www.sealey.co.uk, email [email protected] or telephone 01284 757500.

 

Environmental Protection

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be 

sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.

When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)

into approved containers and dispose of the product and the fluids according to local regulations.

WEEE Regulations

Dispose of this product at the end of its working life in compliance with the EU Directive on 

Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed

of in an environmentally protective way. Contact your local solid waste authority for recycling information.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Original Language Version

 © Jack Sealey Limited

G1050I, G2000I     Issue: 1 - 06/06/14

7.3. 

SPaRK PLuG

 

RECOMMENDED SPARK PLUG: A7RTC or equivalent.

 

To ensure proper engine operation, the spark plug must be properly gapped and free of deposits.

7.3.1.  

Remove the spark plug maintenance cover (fig.13).

7.3.2. 

Remove the spark plug cap (fig.14).

7.3.3. 

Clean any dirt from around the spark plug base.

7.3.4.  

Use the wrench to remove the spark plug.

7.3.5.  

Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the spark plug with a wire brush if it is to be    

 reused.

7.3.6.  

Measure the plug gap with a feeler gauge. The gap should be 0.60-0.70mm (0.024-0.028”). Correct as necessary by  

 

 

 

bending the side electrode carefully (fig.15).

7.3.7.  

Install the spark plug carefully, by hand, to avoid cross-threading.

7.3.8.  

After a new spark plug has been seated by hand, it should be tightened 1/2 turn with a wrench to compress its washer.

 

If a used plug is being reinstalled, it should only require 1/8 to 1/4 turn after being seated.

7.3.9.  

Reinstall the spark plug cap on the spark plug securely.

7.3.10.   Reinstall the spark plug maintenance cover.