WARNING! Ensure any Health & Safety, Government, or local authority regulations are adhered to when using this equipment. 

"

Familiarise yourself with the application and limitations, as well as the potential hazards of the generator.

"

Maintain the generator in good condition (use an authorised service agent). Replace or repair damaged parts. Use genuine parts only. 
Unauthorised parts may be dangerous and will invalidate the warranty.

"

This generator is designed and manufactured for specific applications. Do not attempt to modify the unit or use it for any application for 
which it is not designed. If you have any questions regarding the application of the unit please contact your local Sealey dealer.

!

WARNING! DO NOT exceed the Wattage/Amperage capacity of the generator.

Add rated wattage of all devices intended for connection

at any one time. The total must not exceed rated wattage of generator (see specification). In most cases the rated wattage of an electrical 
device can be found on the nameplate. If the nameplate only gives voltage and amperage, multiply the two to give rated wattage (Volts x 
Amps = Watts)

!

WARNING! Generator exhaust gases contain deadly carbon monoxide which must not be inhaled. Always allow sufficient 
ventilation.

!

WARNING! If you decide to use an Earth Leakage Circuit Breaker (also referred to as an RCD or Ground Fault Circuit Interrupter),
it is imperative that the neutral end of the power winding is connected to the frame of the generator set and that the earth lug on 
the frame is connected with a low impedance connector to the local earth via an earth spike or local protective earth conductor. 
This connection should only be attempted by a qualified electrician, after first having consulted your local dealer.

#

DANGER! This generator is designed for outdoor use only. To use the generator inside any building or enclosure, including the 
generator compartment of a caravan, may result in fire or an explosion. No user-performed modifications, including venting of 
the exhaust and/or cooling ventilation, will eliminate the danger.

#

DANGER! If this unit is used for back-up power in the event of a commercial power failure, the following steps must be taken.
Before connecting the generator to the electrical system, open the main circuit breaker to isolate the generator and system from 
the commercial electric supply. Failure to do this may result in damage to the generator and may result in serious injury or
fatality, due to a back-feed of electrical energy.

#

DANGER! The generator produces a very powerful voltage that can cause a severe electrical shock. Avoid contact with bare 
wires, terminals etc. Never allow any unqualified person to operate or service the generator.

!

WARNING! Petrol is highly flammable and petrol vapour is explosive. Do not permit smoking, naked flames, sparks or heat in the
vicinity while handling petrol. Avoid spilling petrol onto a hot engine. Comply with all laws regulating storage and handling of 
fuels.

!

WARNING! NEVER refuel when the engine is running or when the engine is hot. Allow some time for the engine to cool down.

"

Operate the generator only on level surfaces (maximum allowable tilt is 10º) and where it will not be exposed to excessive moisture, dirt 
or corrosive vapours or be in the proximity of combustible material (flammable liquids, solids or gases). 

"

Remove ill fitting clothing, ties, watches, rings and other loose jewellery and contain long hair. Wear appropriate protective clothing.

"

Keep non-essential persons away from the working area.

!

WARNING! Never start or stop the generator while electrical loads are connected and switched on. Start the engine, let it 
stabilise, then connect the electrical load. To stop engine, disconnect the electrical load and let engine stabilise before switching 
off.

!

WARNING! Do not use worn, bare, frayed or otherwise damaged electrical cables with the generator. To do so may result in 
electric shock.

$

DO NOT

use the generator for any purpose other than that for which it is designed.

$

DO NOT

operate the generator if any parts are missing or damaged, as this may cause failure and/or personal injury.

$

DO NOT

over-fill fuel tank. Always leave some room for fuel to expand.

$

DO NOT

operate in the rain.

#

DANGER! Do not tamper with the engine governed speed setting. Higher operating speeds are dangerous and increase the risk 
of personal injury and/or equipment damage. The generator supplies the correct rated frequencies and voltages only when 
running at the correct governed speed. Incorrect frequency and/or voltage can damage some connected electrical loads. 
Operating at excessively low speeds may result in shortened engine life. Over-speeding will invalidate the warranty.

$

DO NOT

operate the generator when you are tired or under the influence of alcohol, drugs or intoxicating medication.

$

DO NOT

store generator with fuel in tank where petrol vapours might reach an open flame or spark.

1. SAFETY INSTRUCTIONS

Motor Power:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.3kW/1.7hp
Motor Type:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-Stroke
Output:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V - 50Hz/12V DC
Current Rating:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.9A/8A
Cont. Power Rating:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .900W
Max Power Rating:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1000W  

Fuel Tank Capacity:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.1ltr
Fuel:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Petrol Unleaded 95 RON
Max Running Time:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5hr
Noise Rating:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94dB.A
Dry Weight:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14kg
Dimensions (L x W x H):  . . . . . . . . . . . . . . . . . . .460 x 235 x 400mm

2. INTRODUCTION & SPECIFICATION

Digital inverter technology provides a stable ‘clean’ output, making the unit suitable for use with sensitive electrical equipment such as
computers. A smart throttle sensor automatically adjusts the engine speed to precisely match the load, which allows the generator to run
quieter whilst increasing fuel efficiency and lengthening engine life. Low oil cut-out and overload protection. 
Fitted with a 12V battery charging outlet and a 230V 3-pin socket.

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND

CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.

G1000E.V2 - 1 - 220806

INSTRUCTIONS FOR:

INVERTER GENERATOR 1000W 

MODEL: 

G1000E.V2

Summary of Contents for G1000E.V2

Page 1: ...ngine is hot Allow some time for the engine to cool down Operate the generator only on level surfaces maximum allowable tilt is 10º and where it will not be exposed to excessive moisture dirt or corrosive vapours or be in the proximity of combustible material flammable liquids solids or gases Remove ill fitting clothing ties watches rings and other loose jewellery and contain long hair Wear approp...

Page 2: ...ap dipstick clean and re insert in the filler hole but do not screw it in If oil level is below the end of the dipstick refill with recommended oil up to the top of the filler neck fig 3 3 1 6 Use only high detergent premium quality 4 stroke engine oil Note The Low Oil Alarm system will automatically stop the engine before the oil level falls below the safe limit but regular checking will avoid in...

Page 3: ... light will remain ON during normal operation If the generator overloads i e in excess of 100W or there is a short in the connected appliance the red overload indicator light fig 2 will illuminate and current to the connected appliance will be cut off 3 4 4 If the red overload indicator light illuminates stop the engine at once and investigate the source of the overloading 3 5 STOPPING THE ENGINE ...

Page 4: ...the Manufacturer and may be inspected by a national authority upon request to Jack Sealey Ltd For Jack Sealey Ltd Sole importer into the UK of Sealey Power Products Signed by Steve Buckle 22nd August 2006 GENERATOR 1000W 230V Model G1000E V2 98 37 EC Machinery Directive 73 23 EEC Low Voltage Directive 89 336 EEC EMC Directive 93 68 EEC Marking Directive G1000E V2 1 220806 7 DECLARATION OF CONFORMI...

Reviews: