background image

Unpack the product and check that there are no missing or damaged parts. If you do experience a problem contact your supplier immediately. 
Your kit should consist of the following:  Spot welder and pneumatic air cooled clamp - 130mm arms (water cooled, 9500 only) and standard
electrodes - with cables. Filter-pressure regulator, gauge and electrovalve (compressed air supply). Water cooler (9500 only). Trolley.

SPECIFICATIONS:

ElectroSpot 8000 ElectroSpot 9500.V2

Power supply  . . . . . . . . . . . . . . . . . .400V(380V-415V)  . . . .400V(380V-415V)

- 1ph-50/60Hz

- 1ph-50/60Hz

Power supply - water cooler  . . . . . . . . . . . . . . . . . .N/A  . .230V - 1ph-50/60Hz 
Electrical protection class  . . . . . . . . . . . . . . . . . . . . . .I  . . . . . . . . . . . . . . . . .I
Insulation class  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .H  . . . . . . . . . . . . . . . .H
Casing protection class . . . . . . . . . . . . . . . . . . . . .IP22  . . . . . . . . . . . . . .IP22
Dimensions with trolley (LxWxH)  . . .650x400x1100mm  . . . .650x400x1100mm

Output

ElectroSpot 8000 ElectroSpot 9500.V2

Secondary no-load voltage (U

0

max)  . . . . . . . . . . .8.6V  . . . . . . . . . . . . . .8.6V

Max welding current (I

2

max)  . . . . . . . . . . . . . . . .4.5kA  . . . . . . . . . . . . . . .7kA

Capacity (low carbon steel)  . . . . . . . .max. 1.5+1.5mm  . . . . . . . .max. 3+3mm
Duty cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3%  . . . . . . . . . . . . . .5.5%
Spots/hour on steel 1+1mm - air cooled clamp  . . . .200  . . . . . . . . . . . . . . .200

water cooled arms  . . . .N/A  . . . . . . . . . . . . . . .400

water cooled arms and clamp  . . . .N/A  . . . . . . . . . . . . . .1000

Max. force at electrodes  . . . . . . . . . . . . . . . . . . .120kg  . . . . . . . . . . . . .120kg
Min. coolant flow  . . . . . . . . . . . . . . . . . . . . . . . . . .N/A  . . . . . . . . . . . . . .2l/m
Automatic spot welding current adjustment.
Automatic spot welding time adjustment to suit sheet thickness and clamp used.

Input

ElectroSpot 8000 ElectroSpot 9500.V2

Max welding power (Smax)  . . . . . . . . . . . . . . . .39kVA  . . . . . . . . . . . . .58kVA
Rated power at 50% (Sn)  . . . . . . . . . . . . . . . . . .6.7kW  .(water cooled)13.0kW
Power factor at Smax (Cos

ϕ)

 . . . . . . . . . . . . . . . .0,65  . . . . . . . . . . . . . .0.65

Delayed mains fuses  . . . . . . . . . . . . . . . . . . . . . . 25A . . . . . . . . . . . . . . .32A
Automatic mains switch  . . . . . . . . . . . . . . . . . . . . .25A . . . . . . . . . . . . . . .32A
Mains cable (L

4m)  . . . . . . . . . . . . . . . . . .3x2.5mm

2

 . . . . . . . . . . . .3x4mm

2

Water cooler  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .N/A  . . . . . . . . . . . . .270W

3. CONTENTS & SPECIFICATIONS

2. INTRODUCTION

An air supply is required to operate the pneumatic clamps. See fig. 1 for the recommended hook-up.
4.1.

Ensure that the air valve is in the "off" position before connecting to the air supply.

4.2.

The pneumatic clamps require a compressed air supply of 6 to 8 bar connected to the filter-regulator at the rear of the welder. 

4.3.

!

WARNING! 

Ensure that the air supply does not exceed 8 bar while operating the welder. Too high an air pressure and/or

unclean air will shorten the product life, due to excessive wear, and may be dangerous, 
causing possible damage and/or personal injury.

4.4.

Drain the air tank daily. Water in the air line will damage the clamp.

4.5.

Clean the compressor air inlet filter screen weekly.

4.6.

Line pressure should be increased to compensate for 
unusually long air hoses (over 8 metres). The minimum 
hose diameter should be 10mm I.D. and fittings must 
have the same inside dimensions.

4.7.

Keep hoses away from heat, oil and sharp edges. 
Check hoses for wear, and make certain that 
all connections are secure.

4. AIR SUPPLY

5. TROLLEY ASSEMBLY

fig. 1

Microprocessor controlled power unit with push-button control automatically recognises which welding accessories are fitted and adapts power
and duration characteristics for optimum results. Includes operator override. Features pulse facility for welding high stress materials. Check-
panel indicates machine status including: supply, thermostat, supply over/under voltage. Piggy-back water-cooler cools both power cables and
arms for maximum duty-cycle (9500 only). Supplied with pneumatic pincers and set of arms. Includes trolley.

A diagram showing the assembly of the trolley may be found at the end of these Instructions.

!

WARNING! DO NOT 

attempt to put the spot welder onto the trolley until you are certain that all the trolley assembly fixings are tight and

that the wheels have been correctly mounted.

ELECTROSPOT 8000 

(With ‘optional’ gun 801045)

ElectroSpot 8000/9500.V2 - 2 - 040903

Summary of Contents for ELECTROSPOT 8000

Page 1: ...Models ElectroSpot 8000 9500 V2 2 040903 ELECTROSPOT 9500 V2 ELECTROSPOT 8000 ELECTROSPOT 9500 V2 INSTRUCTIONS FOR SPOT W WELDERS ...

Page 2: ...cting to mains power supply 1 1 4 Ensure that cables are always protected against short circuit and overload 1 1 5 Regularly inspect power supply leads plugs and all electrical connections for wear and damage and especially power connections to ensure that none is loose 1 1 6 Important Ensure that the voltage marked on the product is the same as the power supply to be used A three phase plug must ...

Page 3: ...othing to protect yourself from sparks and hot droplets of fused metal Cover exposed flesh to avoid burns DO NOT operate the welder if it or the cables are damaged DO NOT hold or touch the pieces to be welded All workpieces must be suitably clamped DO NOT place your hands near the electrodes danger of burning and or crushing The operator must be fully trained in the use of the welder and must be a...

Page 4: ...ure that the air valve is in the off position before connecting to the air supply 4 2 The pneumatic clamps require a compressed air supply of 6 to 8 bar connected to the filter regulator at the rear of the welder 4 3 WARNING Ensure that the air supply does not exceed 8 bar while operating the welder Too high an air pressure and or unclean air will shorten the product life due to excessive wear and...

Page 5: ...ND CABLE CONNECTION fig 3 6 3 1 Connect the two Dinse plugs into the welder sockets 6 3 2 Plug in control cable 6 4 AIR PULLER GROUND CABLE CONNECTION fig 4 6 4 1 Connect the two Dinse plugs into the welder sockets 6 4 2 Plug in air line from puller to welder air outlet and connect control cable 7 FRONT PANEL ELECTROSPOT 8000 fig 2 fig 5 The following describes the functions of the front panel key...

Page 6: ... two Dinse adaptors to the welder output plates 8 4 2 Plug the Dinse plugs into the adaptors and connect the control cable 8 5 AIR PULLER GROUND CABLE CONNECTION fig 9 8 5 1 Connect the two Dinse adaptors to the welder output plates 8 5 2 Connect the two Dinse plugs into the adaptors 8 5 3 Plug air line from puller into welder air outlet and connect control cable 8 6 DOUBLE SPOT CLAMP CONNECTION P...

Page 7: ...The lower arm should be inserted fully into its socket and secured with the two grub screws provided Adjust the upward protrusion of the short electrode to 22mm and ensure that it is vertical The upper arm and electrode should then be adjusted so that the electrodes are vertically aligned when viewed from the front and so that the tips coincide when the clamp closes When at rest the distance betwe...

Page 8: ...ng current for a pre set time Welding is indicated by the green LED Release the clamp lever a few moments after the LED goes out This delay in releasing the clamp load improves the mechanical strength of the weld Operate the pneumatic clamp with a regulated air supply of 4 to 8 bar 10 2 4 HOW TO USE THE STUDDER To assemble or disassemble electrodes use two hex wrenches one to prevent the clamp spi...

Page 9: ...p push button and keep it pressed Move the electrode during each pause in the weld pause cycle provided by the machine The work pause cycles are controlled automatically by the spot welder according to sheet thickness Keep a light pressure on the electrode 3 4kg and weld along a line ideally 2 3mm in from the edge of the new piece To achieve good results DO NOT weld more than 300mm from ground poi...

Page 10: ...20 132299 Mains Cable 2 5mm2 x 4m 12 120 990598 Auxiliary Transformer 13 120 169209 Transformer 400V ITEM PART NO DESCRIPTION 14 120 313551 Front Panel Card 15 120 322472 Front Panel 16 120 649338 Bottom 17 120 655232 Cover 18 120 712037 Dinse Socket DX 70 95 19 120 602022 Manometer 20 120 602071 Air Regulator 21 120 602086 Glass for Regulator 22 120 990046 Bushing Nut Cable 23 120 602116 Quick Co...

Page 11: ... 7 120 432382 FIXED ELECTRODE HOLDER 8 120 432383 MOBILE ELECTRODE HOLDER 9 120 483220 PIN 10 120 483221 PIN ITEM PART NO DESCRIPTION 11 120 483278 BLOCK CABLE 12 120 602157 CYLINDER D 50 13 120 644913 PLATE 14 120 483222 LEVER 15 120 690005 ELECTRODE HOLDER ARM L 120MM 16 120 690047 STRAIGHT ELECTRODE L 130MM D 12MM 17 120 690050 STRAIGHT ELECTRODE L 50MM D 12MM 18 120 713066 CLAMP CABLE 19 120 8...

Page 12: ...5 120 482774 Pin 36 120 602121 Cylinder ITEM PART NO DESCRIPTION 37 120 631010 Pneumatic Clamp Movable Head 38 120 690005 Electrode Holder Arm 120mm 39 120 690047 Straight Electrode 130mm x Ø12mm 40 120 690050 Straight Electrode 50mm x Ø12mm 41 120 713054 Cable 120mm2 x 2m Electrode Holder 42 120 713056 Cable 120mm2 x 2m Electrode Holder 43 120 120111 Switch Cable 44 120 803151 Straight Arms 120mm...

Page 13: ...17 120 990168 Kit Replacing Card 18 120 322481 Front Panel 19 120 322463 Handle ITEM PART NO DESCRIPTION 20 120 322469 Upper Connector Cover 21 120 322470 Lower Connector Cover 22 120 690000 Copper Upper Bar 23 120 690002 Copper Lower Bar 24 120 602000 Quick Connect 25 120 602022 Manometer 26 120 602071 Air Regulator 27 120 602086 Glass for Air Regulator 28 120 602106 Quick Connection 29 120 60210...

Page 14: ...er 53 120 990176 Straight Arms 250mm Electrodes 54 120 990117 Kit Jaw 55 120 990175 Air Cooling Unit Kit ITEM PART NO DESCRIPTION 56 120 990169 Bracket Kit 57 120 712049 Electrode Connection 58 120 713051 Cable 150mm2 x 0 35mm Electrode Holder 59 120 690059 Pincer Air Tube 60 120 122353 Switch Cover 60 120 122381 Switch 61 120 132335 Mains Cable 1 5mm2 x 2m 62 120 152217 Fan Blade 63 120 323001 Fo...

Page 15: ...CIRCUIT DIAGRAMS FOR ELECTROSPOT 8000 ELECTROSPOT 9500 V2 ELECTROSPOT 8000 ELECTROSPOT 9500 V2 ELECTROSPOT 9500 COOLER Issue 2 Date Issued 040903 ...

Page 16: ...TROLLEY ASSEMBLY DIAGRAM FOR ELECTROSPOT 8000 TROLLEY ASSEMBLY DIAGRAMS FOR ELECTROSPOT 9500 V2 Issue 2 Date Issued 100807 Issue 1 Date Issued 270602 ...

Page 17: ......

Page 18: ...Edmunds Suffolk 01284 757500 sales sealey co uk 01284 703534 e mail Web www sealey co uk SPOT WELDERS Models ELECTROSPOT 8000 ELECTROSPOT 9500 V2 SPOT WELDERS Models ELECTROSPOT 8000 ELECTROSPOT 9000 V2 73 23 EEC Low Voltage Directive 89 336 EEC EMC Directive 93 68 EEC Marking Directive We the sole importer into the UK declare that the products listed below are in conformity with the following sta...

Reviews: