Sealey DAS150T.V6 Manual Download Page 2

 

‰

  

WARNING! DO NOT

 sand any materials containing asbestos.

 

8

  

DO NOT

 carry the sander by the electrical cable.

 

8

  

DO NOT 

connect  to a standard vacuum cleaner to extract dust as damage to the cleaner may result.

 

8

  

DO NOT

 get the sander wet or use in damp or wet locations. 

 

8

  

DO NOT

 use the sander with water, the sander is for dry use only.

 

8

  

DO NOT 

operate the sander if you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

8

  

DO NOT

 use where there are flammable liquids, solids or gases such as paint solvents or waste wiping or cleaning rags.

 

8

  

DO NOT

 leave the sander running unattended.

 

8

  

DO NOT

  carry the sander with your finger on the power switch. 

 

9

  

When not in use disconnect from the power supply and store in a safe, dry, childproof area.

2.  INTRODUCTION

P

atented eccentric assembly with sealed double bearings give 9mm orbital diameter. Variable speed control from 2000-4600rpm. Fitted with 

2m mains cable and 3-pin plug. Alloy bevel gear head with smooth composite motor housing for added comfort. Side mounted slider type 

power control with power lock. Supplied with Ø150mm hook-and-loop pad and side handle.

3.  SPECIFICATION

Model No ...........................................................

DAS150T.V6

Pad Size ................................................................. Ø150mm

Thread size .............................................................

5/16”UNF

Motor Power..................................................................

710W

Supply ............................................................................

230V

No load speed .................................................

2000-4600rpm

Orbit Size .................................................................... Ø9mm

Consumables:

Ø

 145mm DA backing pads:

...................................................

 5/16”UNF (soft):

 .................................................

PTC/150SA

H

ook & loop 5/16”UNF (hard):

 .............................

PTC/150VA

Carbon brush: ...............................................

DAS150T.V6-38

4.  ASSEMBLY

 

‰

 

 

WARNING!

 

DO NOT

 plug sander into the mains power supply before it is fully assembled.

 

  Unpack the sander and check contents. The contents should include a spanner, side handle and backing pad, should there be any

 

  damaged or missing parts contact your supplier immediately. Screw handle (fig.1.2) into the hole (right or left side, as required) in the  

 

  head. Screw the sanding pad onto the spindle (fig.1.3). To remove pad, hold spindle with the spanner supplied whilst unscrewing the  

 

 pad.

5.  OPERATION

 

‰

 

 

WARNING!

 Before use, ensure that you have read and understood Section 1 Safety Instructions.

5.1.   

 

Attach the correctly rated sanding disc (not supplied) to the sanding pad.

5.2.   

 

Plug the sander into the mains power supply. 

5.3.   

Ensure that the speed scroll switch is set to the lowest setting before starting the sander (fig.1.4). Grip the handle and turn on by    

 

pushing switch (fig.1.1) forward and then pressing the front of it down until a click is heard. Let go of the switch and the machine will   

 

continue running. Increase the speed of the sander using the variable switch located at the rear of the sander (fig.1.4). 

5.4.   

To release the switch, and stop the sander, press down on the rear section of the switch (fig.1.1) - it will spring to the Off position.

5.5.   

Ensure that the above features are working correctly prior to use.

 

 NOTE:

 The sander is designed for dry use only. 

DO NOT

 use with water or any other liquids.

Original Language Version

© Jack Sealey Limited

D

AS150T.V6    Issue 1   11/08/20

   fig.1

Summary of Contents for DAS150T.V6

Page 1: ...ified electrician Class II products are wired with live brown and neutral blue only are marked with the Class II symbol A Connect the BROWN live wire to the live terminal L B Connect the BLUE neutral wire to the neutral terminal N C After wiring check that there are no bare wires and ensure that all wires have been correctly connected Ensure that the cable outer sheath extends inside the cable res...

Page 2: ...A Hook loop 5 16 UNF hard PTC 150VA Carbon brush DAS150T V6 38 4 ASSEMBLY WARNING DO NOT plug sander into the mains power supply before it is fully assembled Unpack the sander and check contents The contents should include a spanner side handle and backing pad should there be any damaged or missing parts contact your supplier immediately Screw handle fig 1 2 into the hole right or left side as req...

Page 3: ...sealey co uk www sealey co uk ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste All tools accessories and packaging should be sorted taken to a recycling centre and disposed of in a manner which is compatible with the environment When the product becomes completely unserviceable and requires disposal drain any fluids if applicable into approved containers and ...

Page 4: ...ion The state of maintenance of the tool itself is also an important factor a poorly maintained tool will also increase the risk of Hand Arm Vibration Syndrome Health surveillance We recommend a programme of health surveillance to detect early symptoms of vibration injury so that management procedures can be modified accordingly Personal protective equipment We are not aware of any personal protec...

Reviews: