BATTERY  TEST

5.3.1.   

Select BATTERY TEST and press ENTER.

5.3.2. 

  

Press the ◄ ► to select REGULAR/STD or START/STOP battery.

 

REGULAR/STD BATTERY: 

 

FLOODED, AGM FLAT PLATE, AGM SPIRAL, VRLA/GEL

 

START/STOP BATTERY: 

 

AGM FLAT PLATE, EFB

5.3.3. 

  

Press the ◄ ► key to select the battery type.

5.3.4. 

  

Press ENTER to confirm choice.

5.3.5. 

  

Press the ◄ ► key to select the battery rating: CCA/SAE, EN, JIS, DIN, IEC & 

CA/MCA.

5.3.6. 

  

Press ENTER to confirm choice.

5.3.7. 

  

Press the ◄ ► key to input the battery capacity.

 

CCA/SAE: 40~2000

 

EN: 40~1885

 

DIN: 25~1120

 

IEC: 30~1320

 

JIS: By battery type no.

 

CA/MCA 50~2400

5.3.8. 

  

Press the ◄ ► to confirm the temperature.

5.3.9. 

  

Press ENTER to begin the test.

 

RETURN FEATURE: 

 

Before the test is started, the user can return to the previous setting page by pressing ENTER

 

for 2 seconds.

5.3.10.  SURFACE CHARGE: 

 

The battery will hold a surface charge if the engine has been running or after the battery has been charged. The tester may prompt you to  

 

remove the surface charge.

 

 

A. 

Follow the instructions indicating when to turn the headlights on and off or apply a load into the battery.

 

IN VEHICLE: 

BATTERY TEST

XX.XX V

START/STOP

REGULAR/STD

BATTERY TYPE:

AGM FLAT PLATE

SELECT RATING:

CCA/SAE

SELECT CAPACITY:

560CCA/SAE

ABOVE 32°F/0°C?

YES/NO

SURFACE CHARGE 

IN VEHICLE? YES

TURN HEADLIGHTS 

ON FOR 15 SECS

© Jack Sealey Limited

BT2011 | Issue:1  02/03/20

Summary of Contents for BT2011

Page 1: ... parts of the engine clearly 9 Determine the system voltage before using the tester 9 If the tester receives a sharp knock or blow the unit must be checked by a qualified service agent before using 9 If the battery terminals are corroded or dirty clean them before using the tester 9 Keep children and unauthorised persons away from the work area 8 DO NOT dismantle the tester for any reason The test...

Page 2: ...ill proceed to the Home Screen If the connection is poor the display will show CHECK CABLE In this case check cable connections for visible signs of damage as you may need to re connect the clamps to the battery or replace the cable end 5 1 BEFORE TESTING 5 1 1 Before you test a battery in a vehicle turn off the ignition all accessories and loads Close all the vehicle doors and the boot tailgate 5...

Page 3: ...CA MCA 50 2400 5 3 8 Press the to confirm the temperature 5 3 9 Press ENTER to begin the test RETURN FEATURE Before the test is started the user can return to the previous setting page by pressing ENTER for 2 seconds 5 3 10 SURFACE CHARGE The battery will hold a surface charge if the engine has been running or after the battery has been charged The tester may prompt you to remove the surface charg...

Page 4: ... the engine gradually The battery may fail under extreme climate conditions There may be a poor connection between the vehicle and the battery affect the charging function Please pay attention to the battery for replacement consideration and charging system checking RECHARGE RETEST Battery is discharged the battery condition cannot be determined until it is fully charged Recharge and retest the ba...

Page 5: ...vehicle accessory loads such as lights air conditioning radio etc before starting the engine 5 4 3 When the engine is started one of three results will be displayed along with the actual reading measured CRANKING VOLTS NORMAL The system is showing normal draw Press ENTER to perform the charging system test CRANKING VOLTS LOW The cranking voltage is below normal limits Troubleshoot the starter acco...

Page 6: ...gine running If the belts are slipping or broken replace the belts and retest Check the connections from the alternator to the battery If the connection is loose or heavily corroded clean or replace the cable and retest If the belts and connections are in good condition replace the alternator 5 4 6 Press ENTER for the charging system with accessory loads Turn on the blower to high heat high beam h...

Page 7: ... the cable and retest If the belts and connections are in good working condition replace the alternator CHARGING SYSTEM NORMAL WHEN TESTED WITH ACCESSORY LOADS The system is showing normal output from the alternator No problem detected 5 4 10 Press ENTER when charging system test is completed Turn all accessory loads and engine off Press ENTER to read the system test results IN VEHICLE TEST This i...

Page 8: ...ly in deep cycle applications is non spillable and therefore can be operated in virtually any position However upside down installation is not recommended Connections must be retorqued and the batteries should be cleaned periodically What is a VRLA battery Valve Regulated Lead Acid Battery This type of battery is sealed Maintenance Free with a Bunce Valve or Valves in the top of them that opens wh...

Reviews: