background image

Fig.1

3.3 

BATTERY TEST

3.3.1 

With battery test screen displayed    

 

press EnTER.

3.3.2 

use the 

 (UP) and 

 (DOWN)

 buttons  

 

to select the battery type:  

 

 

Regular liquid, AGm Flat Plate, AGm  

 

spiral or VRlA/Gel.

 

Press EnTER to confirm choice.

3.3.3 

use the 

 (UP) and 

 (DOWN)

  

 

 

buttons to select the battery rating: sAE,  

 

En, IEc, DIn or JIs.

 

Press EnTER to confirm.

3.3.4 

use the 

 (UP) and 

 (DOWN)

  

 

 

buttons to input the battery capacity of  

 

ccA:

 

sAE:   40 - 2000 

 

En: 

40 - 2100

 

IEc:  

30 - 1500 

 

DIn:  

25 - 1300 

 

JIs: by battery type

 

Press EnTER to begin test.

3.3.5 

battery being tested for a few seconds.

3.3.6 

Press 

 (UP) and 

 (DOWN)

 buttons  

 

to select battery fully charged: 

Yes

 or 

No.  

Press EnTER to confirm  

choice.

3.3.7 

When the test is complete, the lcD   

 

shows the actual volts and ccA or Ah.

 

Press 

 (UP) and 

 (DOWN)

 buttons 

 

to select: sOH (state of Health) or sOc  

 

(state of charge).

One of the following results will be  

 

displayed.

3.3.8 

GOOD & PASS:

 battery is capable of  

 

holding a charge.

3.2 

DISPLAY GENERAL

 

by pressing the 

 (UP) and 

 (DOWN)

 buttons  

 

the display will cycle through the options. Press 

ENTER

  

 

button when the option you require is displayed. 

use the 

 (UP) and 

 (DOWN)

  

buttons to select language or press 

EnTER to commence battery test

use the 

 (UP) and 

 (DOWN)

 

buttons to return to battery test or press 

EnTER to set language.

use the 

 (UP) and 

 (DOWN)

  

buttons to select language.

English, French, German, spanish, 

Italian, Portuguese or Japanese.

Press EnTER to confirm choice and 

return to battery test.

nOTE!  The operator is asked if any accessories are left on as a possible 

cause. If accessories are left on, the operator is instructed to charge and retest 

the battery. If accessories are not left on, the operator is instructed to replace 

the battery since the charging system is working and a good battery should have 

accepted a charge.

Original Language Version

bT2001    Issue: 2 - 07/12/09

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

no liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

Sole UK Distributor, Sealey Group, 

Kempson Way, suffolk business Park

bury st. Edmunds, suffolk,

IP32 7AR

01284 757500

01284 703534

[email protected]

www.sealey.co.uk

Web

email

Battery Type:

Regular liquid. 

AGm Flat Plate.

AGm spiral. 

VRlA/Gel.

Reviews: