background image

  

WARNING! 

Ensure Health & Safety, local authority and general workshop practice regulations are adhered to when using  

 

this equipment.

 

         Read instructions thoroughly to ensure safe and effective use.

 Important! Read instructions in conjunction with

 

vehicle or equipment manufacturer's workshop manual. 

 

 

Maintain the apparatus in good condition (use an authorised service agent). Before each use check condition of each  

 

component. If any component is damaged, replace immediately. Use genuine parts only. Unauthorised parts may not

 

function correctly and will invalidate the warranty. 

 

Use in a suitable work area. Keep area free from unrelated materials and ensure that there is adequate lighting.

 

WARNING! 

Always wear approved eye (or face) and hand protection when pressure leakage testing.

  

Keep children and unauthorised persons away from the working area.

 

DO NOT

 operate the leakage tester when you are tired or under the influence of alcohol, drugs or intoxicating

 medication.

 

DO NOT

 clean the equipment with solvents or other harsh chemicals.

 

DO NOT

 use the leakage tester for any purpose other than that for which it is designed.

  

When not in use return parts to the case, and store it in a safe, dry, childproof location.

InStRUctIonS foR: 

TURBO 

SYSTEM  LEAKAGE TESTER 

   

 

   

ModEl n

o

:

 VS2030

thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly 

maintained, give you years of trouble free performance.

1.  SAFETY INSTRUCTIONS

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/

OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

2. DESCRIPTION

designed to charge the turbo system with a low pressure of regulated workshop mains air supply; to indicate the presence of leaks 

within the system. the kit includes a pressure gauge, a shut off ball valve, a pressure relief valve, a mains air male barbed quick 

coupler and four pairs of system stepped adaptors for use on a wide range of hose sizes. the kit can also be used on cooling

system hoses. All items supplied in a storage case.

Original Language Version

VS2030    Issue: 1 - 21/11/12

 © Jack Sealey limited

4. CONTENTS

Quick coupler

connection.

Pressure relief valve

at rear of regulator.

Pressure regulator

and gauge

flexible hose

coupled to adaptor

3.  TECHNICAL SPECIFICATIONS

Part no          Adaptor sizes

VS2030.01    Ø80/85/90mm

VS2030.02    Ø65/70/75mm

VS2030.03    Ø50/55/60mm

VS2030.04    Ø35/40/45mm 

25psi (1.7bar)

maximum

Zero

Ball valve

(open)

Adaptor

Vernier

(not supplied)

tapered stepped spigot adaptors (system plug)

tapered stepped spigot adaptors (system inlet)

nominal bore sizes

Ø80/85/90

nominal bore sizes

Ø65/70/75

nominal bore sizes 

Ø35/40/45

nominal bore sizes

 Ø50/55/60

Reviews: