4.  seT-UP & oPerATion

4.1  You must use a monitoring device such as a timing light, engine  

 

analyser or multimeter in conjunction with the diesel converter  

 

box in order to be able to read rPM on the devices display.  

 

the most common use for this information will be for setting a  

 

constant engine speed for diesel engine smoke testing. 

 

remember to set up your monitoring device for the correct  

 

number of cylinders.

4.2  ensure that the vehicle ignition is off. locate the fuel pipes  

 

connecting the pump to the fuel injectors. for engine timing  

 

purposes the Piezo clamp should be attached to the pipe  

 

going to the no.1 cylinder.

4.3  fix the Piezo clamp (5) onto a straight section of the Injector  

 

fuel pipe for the no.1 cylinder as close to the pump as possible  

 

in order to get the strongest reading. the Piezo clamp and fuel  

 

pipe should be clean and dry. Make sure that the Piezo clamp  

 

is in full contact with the fuel pipe but 

do not overtighten

 as  

 

this could cause damage to the sensor within the clamp. 

4.4  take the sensor lead and connect the YelloW clip (8) to one  

 

of the adjustable fixings on the clamp and the BlAcK clip (7)  

 

to the same Injector fuel pipe to which the clamp is connected.  

p

 

WArning!

 ensure that the Black sensor clip does not  

 

touch any of the Glow Plugs and associated mountings or  

 

wiring as this may cause a short circuit which could disable  

 

engine operation and may damage any connected monitoring  

 

device.

4.5  take the Power lead and connect the red clamp (2) to the  

 

positive side of the vehicle battery and the BlAcK clamp (1) to  

 

the negative of the battery. 

note:

 the monitoring device used  

 

i.e. A timing light, engine Analyzer or digital Multimeter may  

 

also be powered from the vehicle's battery.

4.6  Attach the inductive pickup from your chosen monitoring device  

 

e.g. a timing light, onto the Pickup loop (3) on the converter  

 

box. If the timing light inductive pickup has an arrow mark,  

 

ensure that the mark is face up when attached to the  Pickup  

 

loop.

4.7    start the engine and allow it to reach operating temperature,  

 

then read the results from the timing light. the Indicator light  

 

on the converter box (4) should flash consistently. If the  

 

indicator light does not flash, check all the connections or  

 

relocate the Piezo clamp to another section of the fuel pipe.  

 

note: low vehicle battery, defective Injector Pump, or lack of  

 

fuel may prevent the Indicator light from flashing.

01284 757500

01284 703534

[email protected]

sole UK Distributor

sealey group,

Bury st. edmunds, suffolk.

www.sealey.co.uk

Web

email

NOTE:

 

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

imPorTAnT: 

no liability is accepted for incorrect use of this product. 

WArrAnTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

inFormATion: 

for a copy of our catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.