background image

AK5063 - 5 - 01/11/07

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. 

IMPORTANT: 

No liability is accepted for incorrect use of this equipment. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION: 

For  a  copy  of  our  latest  catalogue  and  promotions  call  us  on  01284  757525  and  leave  your  full  name  and  address,  including  postcode.

  3.  OPERATING INSTRUCTIONS

fig.4

C

D

01284 757500

01284 703534

[email protected]

Sole UK Distributor

Sealey Group,

Bury St. Edmunds, Suffolk.

www.sealey.co.uk

Email

fig.2

A

fig.1

FEMALE (DOUBLE) 

FLARE

MALE (BUBBLE) 

FLARE

 

WARNING! 

Before using the flaring kit, ensure that you  

 

have read and understood the Safety Instructions    

 

in Section 1.

3.1.  The pipe end to be flared must be cut clean and square and  

 

be de-burred. Use a pipe or tube cutter  (available from your  

 

Sealey dealer).

3.2.   Open the clamp and select the appropriate matching 

 

semi-cylindrical indentations on the two rotating dies.   

 

Insert the prepared end of the pipe between the    

 

rotating dies and grip the handles of the tool,  

 

 

bringing them together forcefully. Adjust the protrusion of  

 

the pipe so that ‘X’ (fig.1) is at least 1/8” to 3/16”    

 

depending on pipe size - the larger the pipe - the    

 

greater ‘X‘ should be. 

3.3.  Grip the clamp firmly to ensure that the pipe does not slip.  

 

Should the hold appear insufficient, turn the cam pivot  

 

adjustment (fig.2.A), thereby repositioning the clamp  

 

handles allowing more pressure to be exerted. 

3.4. 

To form a Male (Bubble) flare (fig.4.C)

 

Proceed as above (3.3), then place the appropriately sized  

 

die in the pipe end (fig.3.B), position the press above the die  

 

and screw down until stiff resistance is felt.

  

Remove the press and check that the flare is symmetrically  

 

formed. 

3.5.  

To form a female (Double) flare (fig.4.D)

 

Proceed as above (3.4) to produce a male (Bubble) flare,  

 

then swivel the flare press, without a die fitted, over the  

 

exposed pipe. 

 

Screw the press down.

 

This will fold the top section of the ‘male’ flare inwards to  

 

form  a female ‘double’ flare (fig.4.D). 

 

Again, check that the flare is symmetrically formed.    

fig.3

B