background image

75L PUMP AWAY MOBILE OIL DRAINER

MODEL NO: 

AK450DX

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

 

 

‰

  

WARNING! 

Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this   

  equipment.

 

‰

   WARNING! DO NOT

 pollute the environment by allowing uncontrolled discharge of waste oil. Replace damaged parts. Use genuine  

  parts only. Non authorised parts may be dangerous and will invalidate the warranty.

 

9

   Keep the drainer clean and in good condition for best and safest performance.

 

9

   Wear appropriate protective clothing.

 

9

   Use drainer in an appropriate working area for its function. Keep area clean and tidy and free from unrelated materials and ensure

 

9

   there is adequate lighting.

 

9

   Ensure the floor is not slippery and wear non slip shoes.

 

9

   Keep children and unauthorised persons away from the working area.

 

9

   Dispose of waste liquids in accordance with local authority regulations.

 

‰

  

WARNING!

 

DO NOT

 allow uncontrolled discharge of fluids thus polluting the environment.

 

8

  

DO NOT

 position drainer in such a way that it will cause potential hazards when moving, holding for draining or storing.

 

IMPORTANT: 

AK450DX must be used in conjunction with a wall mounted air pump, model no: AK450DP in order to discharge waste  

 

oil (not supplied with this unit).

2.  INTRODUCTION

75L Reservoir and telescopic funnel fitted with grid filter. Fitted with female dry-fit coupling for connection to Model No. AK450DP Pump-Away 

Station. Includes full drum indicator.

3.  SPECIFICATION

Model No ............................................................... AK450DX

Capacity ........................................................................... 75L

Collection bowl capacity ................................................... 18L

Gravity discharge ...............................................................no

Gravity feed ..................................................................... yes

Max. height to pan ................................................... 1620mm

Min. height to pan ...................................................... 890mm

Oil discharge pressure (bar) .........................................0.5bar

Pump discharge .................................................................no

Temperature range .......................................................<55°C

4.  ASSEMBLY

4.1. 

  

Unscrew the complete axle assembly from the transportation position. Use the nuts, bolts, and washers that are provided to fit the axle  

 

assembly and position the castor wheels as illustrated in the parts diagram.

4.2. 

  

Screw the drainage tube (item 3) into the collection bowl (item 2).

4.3. 

  

Introduce the drainage tube through the height adjustment adaptor into the reservoir and tighten the scalloped hand wheel (item 4).

4.4. 

  

 Place the filter into the collection bowl (item 2).

5.  OPERATION

5.1. 

 

 

COLLECTION OF WASTE OIL

5.1.1. 

  

If unit has been used to drain a previous vehicle, check the oil level indicator float to ensure there is sufficient remaining capacity left

 

before you use the unit. 

5.1.2.    Place the unit under the raised vehicle and adjust the collection bowl to the desired height and tighten the scalloped hand wheel

 

of the adjustable height adaptor.

5.2. 

  

EVACUATION OF WASTE OIL FROM UNIT

 

‰

  

WARNING!

 Ensure all waste is disposed of in accordance with local regulations.

5.2.1.    Take the discharge hose of wall mounted pump unit AK450DP and connect the female coupling to the male coupling of the pan unit  

 

and evacuate waste accordingly.

5.2.2. 

Refer to 

instruction

manual

Wear eye

protection

Wear 

protective 

gloves

Original Language Version

© Jack Sealey Limited

AK450DX | Issue:4 (3) 20/07/20

Reviews: