ADB06

Issue no: 1 - 19/06/13

 

the user operates the ADB02 again.

5.3.1

   Partial Reset

 

the partial register can be reset by 

 

pressing the reset key when the meter

 

is in standby, meaning when the

 

display screen shows the word 

 “totAl”.

 

After pressing the reset key, during 

 

reset, the display screen first of all 

 

shows all the lit-up digits and then all

 

the digits that are not lit up.

 

 

At the end of the process, a display 

 

page is shown with the reset partial 

 

and the reset total.

 

 

After a few moments, the reset total 

 

is replaced by the non resettable total.

5.3.2 

  Resetting the Reset Total

 

the reset total resetting operation can

 

only be performed after resetting the 

 

partial register. the reset total can in 

 

fact be reset by pressing the reset key 

 

at length while the display screen 

 

shows reset total as on the following 

 

display page:

 

 

schematically, the steps to be taken 

 are:

 

1. Wait for the display to show normal 

 

  standby display page (with total only

 

 displayed).

 

2. Press the reset key quickly.

 

3. the meter starts to reset the partial.

 

4. While the display page showing the 

 

  reset total is displayed. Press the 

 

  reset key again for at least 1 second.

 

5. the display screen again shows all 

 

  the segments of the display followed 

 

  by all the switched-off segments and

 

  finally shows the display page where 

 

  the reset Reset total is shown.

5.4  

Dispensing with Flow Rate Mode Display

 

It is possible to dispense fluids, displaying at the same time:

 

• the dispensed partial.

 

• The Flow Rate in [Partial Unit / minute] as shown on the  

 

  following display page:

 

Procedure for entering this mode:

 

• Wait for the Remote Display to go to standby, meaning the  

 

  display screen shows total only.

 

• Quickly press the cAl key.

 

• start dispensing.

  5.  ADb02 METER OPERATION

5.1 

LCD Display

 

the “lcD” of the MEtER features two numerical registers  

 

and various indications displayed to the user only when the  

 

applicable function so requires.

 Key:

 

1. Partial register (5 figures with moving comma FROM 0.1 to  

 

  99999) indicating the volume dispensed since the reset  

 

  button was last pressed.

 

2. Indication of battery charge.

 

3. Indication of calibration mode.

 

4. Totals register (6 figures with moving comma FROM 0.1 to  

 

  999999), that can indicate two types of total:

 

  4.1. General Total that cannot be reset (TOTAL).

 

  4.2. Resettable total (Reset TOTAL).

 

5. Indication of total multiplication factor (x10 / x100 ).

 

6. Indication of type of total, (totAl / Reset totAl).

 

7. Indication of unit of measurement of totals: l=litres  

 

   

 

 

 

     Gal=Gallons

 

8. Indication of Flow Rate mode.

 

9. Indication of unit of measurement of Partial:  Qts=Quarts

 

   

 

 

 

       Pts=Pints

 

   

 

 

                      l=litres

 

   

 

 

                      Gal=Gallons

 

User Buttons

 

the ADB02 features two buttons (reset and cal) which  

 

individually perform two main functions and, together, other  

 

secondary functions.

 

the main functions performed are:

 

• Reset key - resetting the partial register and resettable  

 

  total (reset total).

 

• cal key - entering instrument calibration mode.

 

Used together, the two keys permit entering configuration  

 

mode, useful for changing the units of measurements and  

 

calibration factor.

5.2 

Daily Use

 

the only operations that need to be done for daily use are  

 

partial and/or resettable total register resetting.

 

occasionally the meter may need to be configured or  

 

calibrated. to do so, please refer to the relevant sections.

 

Below are the two typical normal operation displays.

 

one display page shows the partial and reset total registers.  

 

the other shows the partial and general total. switchover  

 

from resettable total to general total display is automatic and  

 

tied to phases and times that are factory set and cannot be

 changed.

 

NOTE: 6 digits are available for Totals, plus two icons x  

 

10 / x100. The increment sequence is the following:

 

0.0 → 99999.9 → 999999 → 100000 x 10 → 999999 x 10 →  

 

100000 x 100 → 999999 x 100

5.3  

Dispensing in Normal Mode

 

normal mode is the standard dispensing. 

 

While the count is made, the partial and 

 

resettable total are displayed at the same 

 

time (reset total).

 

should one of the keys be accidentally 

 

pressed during dispensing, this will have 

 

no effect.

 

A few seconds after dispensing has 

 

ended, on the lower register, the display 

 

switches from resettable total to general 

 

total: the word reset above the word total 

 

disappears, and the reset total is

 

replaced by the general total.

 

this puts the meter in standby mode and remains stable until  

    Original Language Version 

© Jack sealey limited

Summary of Contents for Adblue ADB06

Page 1: ...ORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED FAILURE TO DO SO MAY CAUSE DAMAGE OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE USE Thank you for purchasing a Sealey product Manufactured to a high standard this product will give you years of trouble free performance if these instructions are carefully followed and the product is cor...

Page 2: ...3 Indication of calibration mode 4 Totals register 6 figures with moving comma FROM 0 1 to 999999 that can indicate two types of Total 4 1 General Total that cannot be reset TOTAL 4 2 Resettable total Reset TOTAL 5 Indication of total multiplication factor x10 x100 6 Indication of type of total TOTAL Reset TOTAL 7 Indication of unit of measurement of Totals L Litres Gal Gallons 8 Indication of Flo...

Page 3: ...nd hold down the CAL button Why enter the calibration phases To display the currently used calibration factor Return to factory k factor after a previous calibration with user k factor Change the calibration factor using one of the two previously indicated procedures In calibration mode the partial and total dispensed quantities indicated on the display screen take on different meanings according ...

Page 4: ...Real value ADB02 calculates the new USER K FACTOR This calculation could require a few seconds depending on the correction to be made During this operation the arrow disappears but the CAL indication remains If this operation is performed after operation 5 4 5 without changing the indicated value the USER K FACTOR would be the same as the FACTORY K FACTOR thus it is ignored 6 4 9 At the end of the...

Page 5: ...ogether with the unit of measurement set at that time in this example Litres Litres 6 6 3 Press the RESET key to select the desired combination of unit of measurement amongst those shown below 6 6 4 Save the new combination by pressing the CAL key at length ADB02 will pass through the start cycle and will then be ready to dispense in the set units q WARNING The Resettable Total and Total registers...

Page 6: ...gue on 01284 757525 and leave your full name and address including your postcode Under the Waste Batteries and Accumulators Regulations 2009 Jack Sealey Ltd are required to inform potential purchasers of products containing batteries as defined within these regulations that they are registered with Valpak s registered compliance scheme Jack Sealey Ltd s Batteries Producer Registration Number BPRN ...

Reviews: