SeaLevel R23008-01 User Manual Download Page 26

                                                                                                                               

               

                                                                             

 

 

26 

 
         © Sealevel Systems, Inc. 

RELIO R2 SYNC Manual   |  SL9255  10/2021 

 

 

Mechanical Drawings, Continued 

Rear view 
 

 

 

Side view 

 

 

 

If no airflow is present in the application environment, orienting the computer so the heat sink fins run 
in the Z direction (vertically up and down) facilitates natural convection improving heat removal.  

 

 

 

Summary of Contents for R23008-01

Page 1: ...1 Sealevel Systems Inc RELIO R2 SYNC Manual SL9255 10 2021 Relio R2 SYNC User Manual RELIO R2 SYNC...

Page 2: ...CTURING 10 SYSTEM OPERATION 11 POWER BUTTON 11 POWER STATES 11 SYNCHRONOUS SERIAL COMMUNICATION PORTS 11 INTERNAL BAUD RATE GENERATOR 11 CONTROL AND STATUS REGISTERS DEFINITION 12 INTERFACE SELECTION...

Page 3: ...m solutions in the fastest time possible Common I O features include serial analog and digital I O Sealevel s extensive library of proven I O circuits can be included as required to meet the specific...

Page 4: ...control signals implemented o Compatible with Sealevel 5402 and 5402e Synchronous cards 1 Display Port Compatible Video Output 2 Gigabit Ethernet Ports 2 USB 2 0 Ports 64GB mSATA Solid State Drive Pow...

Page 5: ...er Supply Desktop 90 264VAC 47 63Hz 21VDC regulated 3000mA output with a KPPX 4P connector Advisory Conventions Warning The highest level of importance used to stress a condition where damage could re...

Page 6: ...he CA104 is a standard DB25F to DB25M serial extension cable Extend a DB25 cable or locate a piece of hardware where it is needed with this six foot 72 inch cable The connectors are pinned one to one...

Page 7: ...30 Twisted Pair Serial Cable 72 inch Length Item CA174 DB25 Female to DB25 Male Twisted Pair Serial Cable 72 inch Length Twisted Pairs provide increased data integrity in high speed serial application...

Page 8: ...with steady state CPU usage greater than 50 some additional cooling must be used to ensure safe operation of the electronics The R2 SYNC computer system is a fan less solid state computer that relies...

Page 9: ...output to the R2 SYNC system Typical power consumption varies depending on COM Express Module memory capacity OS software activity and peripheral devices AC current draw will never exceed 1 4 A All n...

Page 10: ...l Name 1 Positive DC Power 2 Negative DC Power GND 3 Negative DC Power GND 4 Positive DC Power Manufacturing All Sealevel Systems printed circuit boards are built to UL 94V0 rating and are 100 electri...

Page 11: ...standby state by holding the Power Button for 3 seconds The system can also be awoken from S3 or S4 with a USB input device such as a HID compliant keyboard or mouse To be awoken from a standby state...

Page 12: ...D2 SD1 SD0 15 RD SD15 SD14 SD13 SD12 SD11 SD10 SD9 SD8 Field Description IRQST SCC interrupt status 1 No interrupt pending on ESCC 0 Interrupt pending on ESCC DSRA DSRA 1 DSRA not active 0 DSRA active...

Page 13: ...are high impedance 1 0 0 0 1 not supported 2 0 0 1 0 RS 232 3 0 0 1 1 not supported 4 0 1 0 0 RS 485T with 120 termination 5 0 1 0 1 RS 485 without termination 6 7 8 9 0 1 1 0 not supported A 1 0 1 0...

Page 14: ...RTS 19 6 56 31 81 DTR 20 7 57 32 82 DTR 23 8 58 33 83 TSET 24 9 59 34 84 TSET 11 10 60 35 85 RXD 3 11 61 36 86 RXD 16 12 62 37 87 CTS 5 13 63 38 88 CTS 13 14 64 39 89 DSR 6 15 65 40 90 DSR 22 16 66 4...

Page 15: ...Data Output 3 RD Receive Data Input 4 RTS Request To Send Output 5 CTS Clear To Send Input 6 DSR Data Set Ready Input 7 GND Ground 8 DCD Data Carrier Detect Input 15 TXC Transmit Clock Input 17 RXC R...

Page 16: ...gative Output 3 RDA RX Receive Negative Input 7 GND Ground 9 RXCB RXC Receive Clock Positive Input 11 TSETB TSET Transmit Signal Element Timing Output 12 TXCB TXC Transmit Clock Positive Input 14 TDB...

Page 17: ...D Data Carrier Detect Positive Input 11 TSETB TSET Transmit Signal Element Timing Output 12 TXCB TXC Transmit Clock Positive Input 13 CTSB CTS Clear To Send Positive Input 14 TDB TX Transmit Positive...

Page 18: ...Negative Input 9 RXCB RXC Receive Clock Positive Input 11 TSETB TSET Transmit Signal Element Timing Output 12 TXCB TXC Transmit Clock Positive Input 13 CTSB CTS Clear To Send Positive Input 14 TDB TX...

Page 19: ...RXCB RXC Receive Clock Positive X Input 11 TSETB TSET Transmit Signal Element Timing W Output 12 TXCB TXC Transmit Clock Positive AA Input 14 TDB TX Transmit Positive S Output 15 TXCA TXC Transmit Cl...

Page 20: ...replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions To fulfill the requirements of EN 60950 th...

Page 21: ...21 Sealevel Systems Inc RELIO R2 SYNC Manual SL9255 10 2021 Rear Panel I O Connectors...

Page 22: ...22 Sealevel Systems Inc RELIO R2 SYNC Manual SL9255 10 2021 Mechanical Drawings Top View...

Page 23: ...Continued Bottom View The mounting brackets included with the computer allow options for two methods Flush Mounting If the computer is to be mounted to a thermally conductive surface it is recommended...

Page 24: ...24 Sealevel Systems Inc RELIO R2 SYNC Manual SL9255 10 2021 Mechanical Drawings Continued Front View Rear View...

Page 25: ...Raised Mounting If the computer is to be mounted to a thermally insulating surface such as a plastic or wood surface it is recommended to use the method that raises the computer 0 5 off the surface T...

Page 26: ...2021 Mechanical Drawings Continued Rear view Side view If no airflow is present in the application environment orienting the computer so the heat sink fins run in the Z direction vertically up and dow...

Page 27: ...wise unavailable or if desired the current versions of Sealevel software packages can be obtained from the Sealevel website see following instructions If you already have the Sealevel software proceed...

Page 28: ...t and enter the BIOS 3 Press the F9 key to load optimal defaults then press enter to validate the change 4 Press the following key pattern Right arrow Enter Down arrow 9 times Enter Up arrow Enter F10...

Page 29: ...ctrostatically sensitive components in protective packaging or on anti static mats Grounding Methods The following measures help to avoid electrostatic damages to the device Cover workstations with ap...

Page 30: ...DTE and Data Circuit Terminating Equipment DCE RS 485 RS 485 is backwardly compatible with RS 422 however it is optimized for party line or multi drop applications The output of the RS 485 driver is c...

Page 31: ...d by the transmission of a pre defined number of stop bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits The diagram below demonstrates asynchronous c...

Page 32: ...m neglect abuse accidents or acts of nature are not covered under this warranty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees t...

Reviews: