background image

 

14 

© Sealevel Systems, Inc.  7104 Manual   |   SL9051  7/2021 

Appendix C 

 Electrical Interface 

RS-232 

Quite possibly the most widely used communication standard is RS-232. This implementation has been 
defined and revised several times and is often referred to as RS-232 or EIA/TIA-232. The IBM PC computer 
defined  the  RS-232  port  on  a  9  pin  D  sub  connector  and  subsequently  the  EIA/TIA  approved  this 
implementation as the EIA/TIA-574 standard. This standard is defined as the 

9-Position Non-Synchronous 

Interface between Data Terminal Equipment and Data Circuit-Terminating Equipment Employing Serial Binary 
Data Interchange

. Both implementations are in widespread use and will be referred to as RS-232 in this 

document. RS-232 is capable of operating at data rates up to 20 Kbps at distances less than 50 ft. The 
absolute maximum data rate may vary due to line conditions and cable lengths. RS-232 is a single ended 
or unbalanced interface, meaning that a single electrical signal is compared to a common signal (ground) 
to determine binary logic states. The RS-232 and the EIA/TIA-574 specification define two types of interface 
circuits,  Data  Terminal  Equipment  (DTE)  and  Data  Circuit-Terminating  Equipment  (DCE).  The 
COMM+850.LPCI

 

is a DTE device.  

 

 

 

Summary of Contents for COMM+850.LPCI

Page 1: ...1 Sealevel Systems Inc 7104 Manual SL9051 7 2021 COMM 850 LPCI User Manual 7104...

Page 2: ...CARD SETUP 5 INSTALLATION 7 PHYSICAL INSTALLATION 9 TECHNICAL DESCRIPTION 10 SPECIFICATIONS 11 APPENDIX A TROUBLESHOOTING 12 APPENDIX B HOW TO GET ASSISTANCE 13 APPENDIX C ELECTRICAL INTERFACE 14 APPE...

Page 3: ...ta rates up to 460 8K bps The board meets the requirements for the MD1 Low Profile specification as defined by PCISIG in PCI 2 2 Low Profile Addendum The COMM 850 LPCI also features Universal Bus 3 3...

Page 4: ...ips with a standard size PCI bracket Advisory Conventions Warning The highest level of importance used to stress a condition where damage could result to the product or the user could suffer serious i...

Page 5: ...Baud rates commonly associated with COM ports i e 2400 4800 9600 19 2 115 2K bps place the jumper in the divide by 4 mode silk screen D4 position To select the maximum data rates up to 460 8K bps plac...

Page 6: ...ns package allows the use of Baud rate divisors choose the appropriate divisor from the following table For this Data Rate Choose this Divisor 1200 bps 384 2400 bps 192 4800 bps 96 9600 bps 48 19 2K b...

Page 7: ...elect Download Now for SeaCOM for Windows 4 The setup files will automatically detect the operating environment and install the proper components Follow the information presented on the screens that f...

Page 8: ...f files both explains typical Linux serial implementations and informs the user about Linux syntax and preferred practices User can use a program such as 7 Zip to extract the tar gz file In addition t...

Page 9: ...n the machine until the software has been fully installed 1 Turn off PC power Disconnect the power cord 2 Remove the PC case cover 3 Locate an available PCI slot and remove the blank metal slot cover...

Page 10: ...tures programmable baud rates data format interrupt control and industry leading 128 byte FIFOs Connector Pin Assignments RS 232 DB 9 Male Name Pin Mode TD Transmit Data 3 Output RTS Request To Send 7...

Page 11: ...ing Manufacturing All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100 electrically tested These printed circuit boards are solder mask over bare copper or solder mask o...

Page 12: ...ating system Some BIOS setup software will allow changing the IRQ but others do not Another method of changing assigned resources is to try changing PCI slots This will typically cause the BIOS or OS...

Page 13: ...an FAQ section on its web site Please refer to this to answer many common questions This section can be found at http www sealevel com faq asp 4 Sealevel Systems maintains a web page on the Internet...

Page 14: ...Terminal Equipment and Data Circuit Terminating Equipment Employing Serial Binary Data Interchange Both implementations are in widespread use and will be referred to as RS 232 in this document RS 232...

Page 15: ...e character is defined by the transmission of a pre defined number of stop bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits Figure 1 Asynchronous Co...

Page 16: ...16 Sealevel Systems Inc 7104 Manual SL9051 7 2021 Appendix E Silk Screen 2 536 4 721...

Page 17: ...to correct the interference at the user s expense EMC Directive Statement Products bearing the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23...

Page 18: ...y Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prepay...

Reviews: