Seal-A-Tron
3815 S.E. Naef Rd. Portland, OR 97267
Ph # 503-652-5200
Installing Seal Wires
Remove broken wires. See Owners Manual for instructions.
Install the new front wire first. With the Take-Up Assembly pushed in, feed the wire
through the hole, pull and fasten it with the bolt.
Next, attach the cross wire to the Take-Up Assembly. Push in the Take-Up Assembly
and Arrest in place with the pin. Slide the supplied brass tube over the seal-wire free
end.
IMPORTANT: Make sure the brass tube end is about ¼
” away from the intersecting
front wire. Bend the tube and wire over the front L-Bar and secure it with the clamp.
The seal wire must rest as close to the ceramic beads as possible. Use a small hammer
to bend the brass tube 90 degrees over the front L-Bar edge. Release Take-Up
Assemblies.
NOTE: failing to install the tube will result in poor seals and broken wires. Replace seal-
wires only with genuine Seal-A-Tron wires. Other brand seal-wires may cause machine
failure, poor seals, and warranty cancellation.