TROUBLESHOOTING
Display
Indication
Description
Reset
condition
Troubleshooting
ALARM
33
MOTOR
FAULT
Flywheel
not
spinning
when
RUN
commanded.
Motor
off
for
1
minute
1)
Verify
boat's
AC
breaker
supplying
power
to
the
Gyro
is
on.
2)
Refer
to
Seakeeper
Drawing
90149
Cable
Block
Diagram
&
check
for
AC
power.
3)
Check
connectors
on
Motor
Drive
Box.
ALARM
35
DISPLAY
FAULT
Display
not
communicating
with
Control
Box
Display
operational
for
1
minute
Refer
to
Seakeeper
Drawing
90149
Cable
Block
Diagram
&
check
Display
connector
on
Serial
Comms
Connection
Box.
ALARM
36
MOTOR
OVERSPEED
Motor
speed
is
over
5.6
KRPM.
Motor
speed
below
5.6
KRPM.
1)
Check
connectors
on
Motor
Drive
Box
and
Gyro
Control
Box.
2)
Contact
Seakeeper
distributor
for
service.
ALARM
37
GYRO
TRAVEL
FAULT
Gyro
angular
rate
high
near
mechanical
stop
(none)
1)
Refer
to
Seakeeper
Drawing
90157
Model
8000
Gyro
Assembly
and
Parts
List
under
Port
Side
View
and
confirm
sensor
is
still
firmly
mounted
to
Gyro.
2)
Inspect
the
brake
system,
including
electrical,
mechanical
and
hydraulic
connections.
ALARM
38
GYRO
MOTION
FAULT
Gyro
angular
rate
more
than
150
degrees
per
second
(none)
1)
Refer
to
Seakeeper
Drawing
90157
Model
8000
Gyro
Assembly
and
Parts
List
under
Port
Side
View
and
confirm
sensor
is
still
firmly
mounted
to
Gyro.
2)
Inspect
the
brake
system,
including
electrical,
mechanical
and
hydraulic
connections.
ALARM
40
INPUT
POWER
HIGH
DC
power
to
Control
Box
above
32V
DC
power
between
17V
and
32V
Verify
DC
input
power
is
between
17V
and
32V;
excessive
load
ALARM
41
INPUT
POWER
LOW
DC
power
to
Control
Box
below
17V
DC
power
between
17V
and
32V
Verify
DC
input
power
is
between
17V
and
32V;
excessive
load
ALARM
42
CONTROL
POWER
HIGH
DC
power
to
brake
and
coolant
pump
above
32V
DC
control
power
between
17V
and
32V
Verify
DC
input
power
is
between
17V
and
32V;
excessive
load
ALARM
43
CONTROL
POWER
HIGH
DC
power
to
brake
and
coolant
pump
below
17V
DC
control
power
between
17V
and
32V
Verify
DC
input
power
is
between
17V
and
32V;
excessive
load
ALARM
44
SENSOR
POWER
HIGH
DC
power
from
Control
Box
to
Gyro
Angle
Sensor
and
Motor
Drive
Box
above
5.25
V.
DC
power
from
Control
Box
to
between
4.75
V
and
5.25
V.
Inspect
gyro
angle
sensor
for
damage
ALARM
45
SENSOR
POWER
LOW
DC
power
from
Control
Box
to
Gyro
Angle
Sensor
and
Motor
Drive
Box
below
4.75
V.
DC
power
from
Control
Box
to
between
4.75
V
and
5.25
V.
Inspect
gyro
angle
sensor
for
damage
Summary of Contents for 8000 GYRO
Page 1: ...Rev 3 JULY 2013 OPERATION MANUAL MODEL 8000 GYRO...
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 4: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 16: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 28: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 40: ...THIS PAGE INTENTIONALLY LEFT BLANK...