background image

Operating Instructions

1. Start the Machine

Press the power key to turn the machine on.

2. Adjust the Settings

Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%).

3. Stop the Machine

Press the power key again and the machine will stop. Note the fan will continue to operate

for 1 minute after the unit has turned off. NOTE: Do not disconnect the power cord to force 

unit to stop. Always use the power button.

4

Water Drainage

During normal operation, the Watchdog 550 will automatically drain by the force of gravity.

If you want to move or store your machine, wait at least 10 minutes to allow the machine

to completely defost, then lean unit gently towards drain to ensure that it is completely

drained.

Watchdog550 Diagram

Front View

7

Drain Connect

 

5. Continuous 

will appear on the display to indicate continuous mode. 

Press this button to switch the unit into continuous mode.

6. Drain Pump

 

Use this button if the unit will not be in use for an extended period of time.  Pressing the drain pump button will remove 

water from the pump reservoir, so the unit can be safely moved or stored. NOTE: THIS FUNCTION IS ONLY 

AVAILABLE ON THE WATCHDOG 900c model. 

 

  

A5/A6 Aux. 

Terminal

For Optional Cond. Pump

Summary of Contents for WATCHDOG550

Page 1: ...Installation Operations Manual WatchDog550 Seaira Global LLC 14021 NC Hwy 50 Surf City NC 28445 Phone 910 660 0962 ...

Page 2: ...Notes 2 3 Electrical Supply 3 Principle of Operation 3 Installation 3 Key Functions 4 Indicator Lights 5 Remote Control 6 Operating Instructions 7 Diagram 7 Maintenance 8 9 Ducted Applications 9 Troubleshooting 10 Spare Parts 11 Warranty Information 12 ...

Page 3: ...ot use water to clean the exterior of the machine To clean unit unplug from power then use a damp cloth to wipe exterior Do not stand on the machine or use it as a device to hang clothes 2 Safety Notes Congratulations on purchasing a new Watchdog Dehumidifier Your new dehumidifier comes with an extensive warranty plan To register simply fill out and return the warranty form provided in the dehumid...

Page 4: ...o reduce risk of injury 1 1 Disconnect electrical power before servicing 2 2 Only plug unit into grounded electrical circuit 3 3 Do not use an extension cord 4 4 Do not use a plug adapter Principle of Operation Installation The area to be controlled should be sealed with a vapor barrier If unit is installed in a crawlspace all vents should be sealed WARNING 3 The Watchdog Series Dehumidifiers util...

Page 5: ... of the tubing into the 3 4 pipe so that it does not extend into the elbow fitting For proper flow a minimum downward slope of 1 per 10 run is required Note If a proper downward angle is not possible then it is recommended to use a Watchdog 900c which includes an integrated pump Alternatively you can use an external condensate pump 4 5 5 Always test the drain before leaving the installation area S...

Page 6: ...WatchDog 550 When set to continuous the dehumidifier will run constantly regardless of the humidity level To stop the machine turn the unit off or switch back to normal humidistat operation If you would like to switch back to normal humidistat operation simply move the setpoint above 36 4 Central Control 13 Indicator Lights 1 Humidity Display Screen The display screen has two functions 1 When the ...

Page 7: ...m and ducted into a living room The remote would then be mounted in the living room so the remote sensor can control the humidity and provide easy controls for the user Another useful application for the remote control is if the dehumidifier is in area that s difficult to access on a regular basis For instance if your dehumidifier is installed in your crawl space the remote could be mounted in you...

Page 8: ...ly drain by the force of gravity If you want to move or store your machine wait at least 10 minutes to allow the machine to completely defost then lean unit gently towards drain to ensure that it is completely drained Watchdog550 Diagram Front View 7 Drain Connect 5 Continuous will appear on the display to indicate continuous mode Press this button to switch the unit into continuous mode 6 Drain P...

Page 9: ...hine body Use a soft damp cloth to clean exterior of unit Do not use any soap or solvents 1 1 Unplug the unit 1 2 3 Clean the filter mesh by vacuuming or washing with warm water no soap or solvents 3 unit 4 Coil Maintenance Once per year clean the coils with an approved coil cleaner 8 MERV 8 Filter ...

Page 10: ...o keep in mind that the supply ducting can be screwed into an adapter if necessary Ducting Installation Note The supply duct adapter is standard on all units Removing Supply Duct Adapter If it is necessary to remove the adapter place hand at bottom of adapter and use your fingers to pull out and down on base of adapter This will lift hooks out of cover holes Installing Supply Duct Adapter To insta...

Page 11: ...n manual Air Inlet or Outlet is Blocked Clear the blockage from inlet or outlet Machine Is Not Level Filter Mesh is Blocked instructions listed in manual Trouble Code E 1 E1 Humidity Sensor Issues Check to ensure that wire is connected at both ends If no issues are visible the sensor may be faulty Trouble Code HI or LO F or F Display LO The unit is outside the operating temperature range Modify th...

Page 12: ...ly W 110 WatchDog 550 Duct Kit Assembly Includes W 104 and W 100 W 125 W 612 Coil Assembly W 613 Hot Gas Valve Assembly Fan Components Fan Components W 600 WatchDog550 Fan Motor W 601 Watchdog550 Complete Fan Assembly W 602 Fan Capacitor Display Control Board Display Control Board W 155 WatchDog 550 Main Control Board W 165 WatchDog 550 Display Board W 170 Seaira RH Temperature Sensor Misc Parts M...

Page 13: ...mited to palletizing wrapping labeling and pickup are associated with customer 4 If shipped customer is responsible for all risk of loss or damage WARRANTY PROCEDURE 1 Customer must mail in warranty registration card on page 13 to Seaira Global If no card is submitted warranty period will begin the day the shipment left the Seaira warehouse Please be sure to record serial and date of installation ...

Page 14: ...THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE SEAIRA GLOBAL S TOTAL LIABILITY REGARDLESS OF NATURE OF CLAIM SHALL NOT EXCEED ORIGINAL PURCHASE PRICE OF THE PRODUCT IF A PRODUCT OR COMPONENT IS REPLACED WHILE UNDER WARRANTY THE APPLICABLE WARRANTY ...

Reviews: