Seaira Global WatchDog NXT120C Installation And Operation Manual Download Page 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Installation

 

1. Place dehumidifier on a level surface.

    • Do not place unit directly on vapor barrier. For example, use blocks 

      or pavers to create a level surface. 

    • If unit has been turned or flipped so that the compressor did not

      remain upright, place the unit on a level surface and wait a

      minimum of 2 hours before proceeding.

2. Set up the drain line

    • Remove the compression nut and slide it over the end of the hose 

      to be attached to unit. 

    • Slide the side of hose with compression nut over the insert on the 

      compression fitting completely. 

    • Tighten compression nut. 

3. Plug dehumidifier into a dedicated 15 amp GFCI protected outlet. 

  

 

                                 

Key Functions

 

1. Power Key

                                         

                                     

• Use this button to turn the dehumidifier on and off.

• Press once to turn machine on. You will hear two beeps and 

  the        light will illuminate green (solid or flashing depending on 

  mode).

• Press the power button a second time and you will hear one beep 

as the machine shuts down. Note that there is a 1 minute fan delay.                                       

2. Arrow Buttons

                                       

• Use the up and down arrows to set the desired humidity setpoint 

  on the display screen.

• The setpoint can be any number between 36%-90%. When the 

  indoor humidity is higher than the setpoint, the unit will operate.

 • Keep in mind that the displayed humidity levels are approximate 

  ( +/-5%)

                                      

3. Continuous Mode

                                       

• To set the unit to run continuously regardless of humidity, 

  simply use the down arrow key to set the humidity below 36%.

• The continuous light will illuminate green and the display will show 

  “CO”.

                                 

Summary of Contents for WatchDog NXT120C

Page 1: ...Installation and Operations Manual Seaira Global LLC 14021 NC Highway 50 Surf City NC 28445 910 660 0962 WatchDog NXT120C...

Page 2: ...ow it Works Installation Requirements Installation Key Functions Indicator Lights Remote Control Operating Instructions Unit Diagram Maintenance Dehumidifier Storage Ducted Applications Troubleshootin...

Page 3: ...charge Do not use water to clean the exterior of the dehumidifier To clean unit unplug from power then use a damp cloth to wipe the exterior Do not stand on dehumidifier or place objects on it Do not...

Page 4: ...il which is cooler than the dew point of air This means moisture will condense out of the air The air is then reheated through the condenser coil and distributed back into the room Installation Requir...

Page 5: ...Functions 1 Power Key Use this button to turn the dehumidifier on and off Press once to turn machine on You will hear two beeps and the light will illuminate green solid or flashing depending on mode...

Page 6: ...ically and the display will show E4 After a 1 minute delay the fan motor will turn off and the dehumidifier will not operate until the problem has been resolved Check to verify that the pump is functi...

Page 7: ...ted If the humidity is above the setpoint the light will be solid green and the machine will operate If the humidity is below the setpoint the unit will be in standby mode and the light will be flashi...

Page 8: ...he machine will start running Press the button againto turn the machine off 2 Up Button Down Button Use the up and down arrows to adjust the humidity level 3 Mode Use the mode button to switch between...

Page 9: ...continue to operate for 1 minute after the unit has shut off DO NOT DISCONNECT THE POWER CORD TO FORCE THE UNIT TO STOP 4 Water Drainage The WatchDog NXT120c has an integrated condensate pump During...

Page 10: ...re doing any maintenance Cleaning the Machine Body Use a soft damp cloth to clean the exterior of unit Do not use any soap or solvents Coil Maintenance Once per year clean the coils with an approved c...

Page 11: ...e desired drain The pump requires routine maintenance that is not covered by the warranty Preventative maintenance is necessary to prevent issues from dirt and slime that may accumulate in the drain s...

Page 12: ...l does not appear clean move on to Advanced Cleaning Complete about once per year depending on environment Advanced Pump Cleaning Complete as needed 1 Press the drain button to drain the water from th...

Page 13: ...Ducted Applications Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent room Both the inlet return grille and the supply grille are designed for 10 flex ducting D...

Page 14: ...13 Troubleshooting...

Page 15: ...if the pump is operational by pressing the drain button Check if the pump energizes and de energizes properly Additionally check to see if any water purged from the system 3 If you haven t cleaned th...

Page 16: ...e day the shipment left the warehouse Please be sure to record serial and date of installation in the spaces provided on page 2 of the manual You will need this information to receive an RA number 2 I...

Page 17: ...D LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE SEAIRA GLOBAL S TO...