![Seagate ST9100828A - Momentus 5400.3 100 GB Hard Drive Product Manual Download Page 27](http://html1.mh-extra.com/html/seagate/st9100828a-momentus-5400-3-100-gb-hard-drive/st9100828a-momentus-5400-3-100-gb-hard-drive_product-manual_1222143027.webp)
Momentus 5400.3 PATA Product Manual, Rev. A
17
2.11
Acoustics
Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-
surements are consistent with ISO document 7779. Sound power measurements are taken under essentially
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.
Note.
For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is
defined by the following equation:
(Number of seeks per second = 0.4 / (average l average access time)
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and
power to operational levels.
2.12
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the rradio frequency (RF) environments defined in the following table:
A - 1) No upset or degradation in performance beyond manufacturer’s specified limits.
2) No data loss.
B - 1) Unit self recovers without user intervention.
2) No data loss.
C - 1) Upset OK provided that unit will function after user intervention.
Table 4:
Drive level acoustics
Models
Idle*
Normal Seek
Performance Seek
2 Discs
ST9160821A
ST9120822A
ST9100828A
2.4 bels (typ)
2.6 bels (max)
2.6
2.8
3.0 bels (typ)
3.2 bels (max)
1 Disc
ST980815A
ST960815A
ST940815A
2.2 bels (typ)
2.4 bels (max)
2.5
2.7
2.9 bels (typ)
3.1 bels (max)
Table 5:
Electromagnetic immunity
Test
Description
Performance
level
Reference
standard
Electrostatic discharge
Contact, HCP, VCP: ± 4
kV; Air:
± 8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 2,000 MHz, 10 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
A
EN 61000-4-3: 96
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz
sine
A
EN 61000-4-6: 97
Power Frequency H-field
immunity
1 A/m, 50Hz/60Hz, 3 axes
A
EN 61000-4-8: 97
Voltage dips, interrupts
30% Reduction for 25 cycles
>95% Reduction for 250 cycles
>95%, 0.5 cycles
C
C
B
EN 61000-4-11: 94
Summary of Contents for ST9100828A - Momentus 5400.3 100 GB Hard Drive
Page 1: ...Momentus 5400 3 ST9160821A ST9120822A ST9100828A ST980815A ST960815A ST940815A ...
Page 2: ......
Page 3: ...Momentus 5400 3 ST9160821A ST9120822A ST9100828A ST980815A ST960815A ST940815A ...
Page 5: ......
Page 6: ...iv Momentus 5400 3 PATA Product Manual Rev A ...
Page 8: ...vi Momentus 5400 3 PATA Product Manual Rev A ...
Page 10: ...viii Momentus 5400 3 PATA Product Manual Rev A ...
Page 12: ...2 Momentus 5400 3 PATA Product Manual Rev A ...
Page 34: ...24 Momentus 5400 3 PATA Product Manual Rev A ...
Page 52: ...42 Momentus 5400 3 PATA Product Manual Rev A ...
Page 56: ...46 Momentus 5400 3 PATA Product Manual Rev A ...
Page 57: ......