Savvio 10K.2 SAS Product Manual, Rev. E
23
7.2.1
Conducted noise immunity
Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz.
Maximum allowed noise values given below are peak-to-peak measurements and apply at the drive power
connector.
7.2.2
Power sequencing
The drive does not require power sequencing. The drive protects against inadvertent writing during power-up
and down.
7.2.3
Current profiles
The +12V and +5V current profiles for the ST9146802SS and ST973402SS models are shown below.
Figure 2.
ST9146802SS current profile
+5v
=
250 mV pp from 0 to 100 kHz to 20 MHz.
+12v
=
800 mV pp from 100 Hz to 8 KHz.
450 mV pp from 8 KHz to 20 KHz.
250 mV pp from 20 KHz to 5 MHz.
Summary of Contents for ST900MM0036
Page 1: ...Product Manual Savvio 10K 2 SAS 100384760 Rev E April 2012 ST9146802SS ST973402SS...
Page 6: ......
Page 75: ......