S
AVVIO
10K.6 SAS P
RODUCT
M
ANUAL
, R
EV
. C
30
450GB models in 3Gb operation
Typical power dissipation under idle conditions in 3Gb operation is 3.36 watts 11.48 BTUs per hour).
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 7). Locate the typical
I/O rate for a drive in your system on the horizontal axis and read the corresp5 volt current, +12 volt current, and total watts
on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123.
Figure 9.
450GB (at 3Gb) DC current and power vs. input/output operations per second
450GB models in 6Gb operation
Typical power dissipation under idle conditions in 6Gb operation is 3.39 watts 11.57 BTUs per hour).
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 7). Locate the typical
I/O rate for a drive in your system on the horizontal axis and read the corresp5 volt current, +12 volt current, and total watts
on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123.
Figure 10.
450GB (at 6Gb) DC current and power vs. input/output operations per second