Barracuda 4LP Product Manual, Rev. D
19
6.0
Physical/electrical specifications
This section provides information relating to the physical and electrical characteristics of the Barracuda 4LP
drive.
6.1
AC power requirements
None
6.2
DC power requirements
The voltage and current requirements for a single drive are shown in the following table. Values indicated apply
at the drive power connector. The single ended power requirements includes the internal disc drive SCSI I/O
termination. The table shows current values in Amperes.
Table 2:
DC power requirements
Notes.
[1]
Measured with average reading DC ammeter. Instant12 V current peaks will exceed these val-
ues.
[2]
A –10% droop is permissible during initial start of spindle, and must return to ±5% before 7,200 rpm is
reached. The ±5% must be maintained after the drive signifies that its power-up sequence has been com-
pleted and that the drive is able to accept selection by the host initiator.
[3]
See +12 V current profile in Figure 3.
[4]
This condition occurs when the Motor Start Option is enabled and the drive has not yet received a Start
Motor command.
[5]
See Section 6.2.1 “Conducted Noise Immunity.” Specified voltage tolerance is inclusive of ripple, noise,
and transient response.
[6]
Operating condition is defined as random seek read operations with a block count of 64 and SCSI discon-
nect enabled.
[7]
General Notes from Table 2:
1.
Minimum current loading for each supply voltage is not less than 4% of the maximum operating current
shown.
2.
The +5 and +12 volt supplies shall employ separate ground returns.
3.
Where power is provided to multiple drives from a common supply, careful consideration for individual drive
power requirements should be noted. Where multiple units are powered on simultaneously, the peak start-
ing current must be available to each device.
Notes
ST34371/ST34571
ST32171/ST32271
N/W/WC
Single-ended
WD/DC
Differential
N/W/WC
Single-ended
WD/DC
Differential
Voltage
+5 V
+12 V
+5 V
+12 V
+5 V
+12 V
+5 V
+12 V
Regulation
[5]
±5%
±5% [2] ±5%
±5%[2] ±5%
±5% [2] ±5%
±5%[2]
Maximum operating current DC3
σ
[1]
0.81
0.95
1.21
0.95
0.81
0.85
1.21
0.85
Average idle current DCX
[1]
0.46
0.54
0.70
0.54
0.46
0.52
0.70
0.52
Maximum starting current
(peak DC) DC3
σ
(peak AC) AC3
σ
[3]
[3]
0.78
2.44
3.1
1.1
2.44
3.1
0.78
2.00
3.1
1.1
2.00
3.1
Delayed motor start (max) DC3
σ
[1][4] 0.48
0.20
0.90
0.20
0.50
0.20
0.90
0.20
Peak operating current
Typical DCX
Maximum DC3
σ
Maximum (Peak) 3
σ
[1][6]
[1][6]
0.75
0.81
1.5
0.76
0.95
2.5
1.05
1.21
2.0
0.76
0.95
2.5
0.72
0.81
1.5
0.73
0.85
2.3
0.91
1.21
2.0
0.73
0.85
2.3