Drive Specification
ST36540A
ST35130A ST33220A
Drive acoustics
(bels—sound power)
Read/Write
mode
4.4 (typical), 4.7 (max)
Nonrecoverable read errors
1 per 10
14
bits read
Mean time between failures
(power-on hours)
300,000
Contact start-stop cycles
(25°C, 40% relative humidity)
40,000
Service life (years)
5
continued from previous page
4
Medalist 6540, 5130 and 3220 Product Manual, Rev. A