24
Barracuda ES.2 SAS Product Manual, Rev. E
[1] Measured with average reading DC ammeter or equivalent sampling scope. Instant12V current
peaks will exceed these values. Power supply at nominal voltage. N (number of drives tested) = 6, 35
Degrees C ambient.
[2] For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching
7,200 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been
completed and that the drive is able to accept selection by the host initiator.
[3] See +12V current profile in Figure 2.
Table 3:
ST3750630SS
DC power requirements
Notes
ST3750630SS
3 Gbit mode
(Amps)
(Amps)
Voltage
+5V
+12V [2]
Regulation
[5]
±5%
±5% [2]
Avg idle current DCX
[1] [6]
0.60
0.50
Maximum starting current
(peak DC) DC
3
σ
[3]
0.90
2.00
(peak AC) AC
3
σ
[3]
1.10
3.50
Delayed motor start (max) DC 3
σ
[1] [4]
0.60
0.17
Peak operating current:
Typical DCX
[1]
0.62
0.78
Maximum DC
3
σ
[1]
0.74
0.82
Maximum (peak) DC
3
σ
1.15
1.75
Table 4:
ST3500620SS
DC power requirements
Notes
3 Gbit mode
(Amps)
(Amps)
Voltage
+5V
+12V [2]
Regulation
[5]
±5%
±5% [2]
Avg idle current DCX
[1] [6]
0.60
0.50
Maximum starting current
(peak DC) DC
3
σ
[3]
0.90
2.00
(peak AC) AC
3
σ
[3]
1.10
3.50
Delayed motor start (max) DC 3
σ
[1] [4]
0.60
0.17
Peak operating current:
Typical DCX
[1]
0.62
0.78
Maximum DC
3
σ
[1]
0.74
0.82
Maximum (peak) DC
3
σ
1.15
1.75
Summary of Contents for BARRACUDA ST3500620SS
Page 6: ...2 Barracuda ES 2 SAS Product Manual Rev E...
Page 10: ...6 Barracuda ES 2 SAS Product Manual Rev E...
Page 14: ...10 Barracuda ES 2 SAS Product Manual Rev E...
Page 26: ...22 Barracuda ES 2 SAS Product Manual Rev E...
Page 46: ...42 Barracuda ES 2 SAS Product Manual Rev E...
Page 74: ...70 Barracuda ES 2 SAS Product Manual Rev E...
Page 81: ......