background image

Seagate BarraCuda Product Manual, Rev. D

16 

www.seagate.com

Drive Specifications

2.9

Acoustics

Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All measurements are
consistent with ISO document 7779. Sound power measurements are taken under essentially free-field conditions over a
reflecting plane. For all tests, the drive is oriented with the cover facing upward.

*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to

operational levels

.

2.9.1 Test for Prominent Discrete Tones (PDTs)

Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this process is the
use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-7) to discern tone
audibility and to compensate for the inaudible components of sound prior to computation of tone ratios according to
Annex D of the ECMA-74 standards.

2.10

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance
when subjected to the radio frequency (RF) environments defined in 

Table 6

.

Note

For seek mode tests, the drive is placed in seek mode only. 
The number of seeks per second is defined by the following equation: 

(Number of seeks per second = 0.4 / (average l average access time

Table 5

Fluid Dynamic Bearing (FDB) motor acoustics

Idle*

Seek

8TB & 6TB models

2.3 bels (typical)
2.5 bels (max)

2.5 bels (typical)
2.6 bels (max)

4TB & 3TB models

2.2 bels (typical)
2.4 bels (max)

2.4 bels (typical)
2.7 bels (max)

2TB models

2.0 bels (typical)
2.1 bels (max)

2.2 bels (typical)
2.3 bels (max)

Table 6

Radio frequency environments

Test

Description

Performance 
level

Reference 
standard

Electrostatic discharge

Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV

B

EN61000-4-2: 95

Radiated RF immunity

80MHz to 1,000MHz, 3 V/m, 
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @ 200Hz

A

EN61000-4-3: 96
ENV50204: 95

Electrical fast transient

± 1 kV on AC mains, ± 0.5 kV on external I/O

B

EN61000-4-4: 95

Surge immunity

± 1 kV differential, ± 2 kV common,
AC mains

B

EN61000-4-5: 95

Conducted RF immunity

150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz sine

A

EN61000-4-6: 97

Voltage dips, interrupts

0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds

C
C
C
B

EN61000-4-11: 94

Summary of Contents for BARRACUDA ST2000DM005

Page 1: ...100805918 Rev D Gen 17 February 2017 Standard models ST8000DM004 ST6000DM003 ST4000DM004 ST3000DM007 ST2000DM005 SATA Product Manual...

Page 2: ...l data rates may vary depending on operating environment and other factors The export or re export of hardware or software containing encryption may be regulated by the U S Department of Commerce Bure...

Page 3: ...stics 16 2 9 1 Test for Prominent Discrete Tones PDTs 16 2 10 Electromagnetic immunity 16 2 11 Warranty 17 2 11 1 Data loss under power interruption with write cache enabled 17 2 11 2 Storage 17 2 12...

Page 4: ...Seagate BarraCuda Product Manual Rev D 3 Figures Figure 1 Attaching SATA cabling 20 Figure 2 Mounting dimensions 1 and 2 disk models 21 Figure 3 Mounting dimensions 3 and 4 disk models 22...

Page 5: ...ation regarding Warranty Support visit http www seagate com support warranty and replacements For information regarding data recovery services visit http www seagate com services software data recover...

Page 6: ...st adapter and SATA disk drive in the current system and expect all of the existing applications to work as normal The SATA interface connects each disk drive in a point to point configuration with th...

Page 7: ...es per sector 4K physical emulated at 512 byte sectors 4096 Default sectors per track 63 Default read write heads 16 Default cylinders 16 383 Recording density max 2294 kB in Track density avg 540 ktr...

Page 8: ...sound power Idle 2 3 bels typical 2 5 bels max Seek 2 5 bels typical 2 6 bels max Non recoverable read errors 1 per 1015 bits read Rated workload Average annualized workload rating 55 TB year The spe...

Page 9: ...m 0 794 in Width max 101 6mm 0 25 4 0 in 0 010 Length max 146 99mm 5 787 in Weight typical 490g 1 08 lb 415g 0 915 lb Average latency 6 0 ms Power on to ready typ 10 0s 8 0s Standby to ready typ 10 0s...

Page 10: ...ized workload rating 55 TB year The specifications for the product assumes the I O workload does not exceed the average annualized workload rate limit of 55 TB year Workloads exceeding the annualized...

Page 11: ...n about 48 bit addressing support of drives with capacities over 137GB 2 3 Default logical geometry Cylinders 16 383 Read write heads 16 Sectors per track 63 LBA mode When addressing these drives in L...

Page 12: ...6 1mm 1 028 in 4TB 3TB 2TB 20 17mm 0 794 in Maximum width 101 6mm 4 0 in 0 010 in Maximum length 146 99mm 5 787 in Typical weight 8TB 630g 1 389 lb 6TB 610g 1 345 lb 4TB 3TB 490g 1 08 lb 2TB 415g 0 91...

Page 13: ...er management modes 2 7 2 Conducted noise Input noise ripple is measured at the host system power supply across an equivalent 80 ohm resistive load on the 12 volt line or an equivalent 15 ohm resistiv...

Page 14: ...wer mode the heads are parked and the spindle is at rest The drive accepts all commands and returns to Active mode when disk access is necessary Sleep mode The drive enters Sleep mode after receiving...

Page 15: ...commend operating at sustained case temperatures above 60 C Operating at higher temperatures will reduce useful life of the product 2 8 2 Temperature gradient 2 8 3 Humidity 2 8 3 1 Relative humidity...

Page 16: ...2TB The non operating shock level that the drive can experience without incurring physical damage or degradation in performance when subsequently put into operation is 350 Gs based on a non repetitiv...

Page 17: ...system the drive operates without errors or degradation in performance when subjected to the radio frequency RF environments defined in Table 6 Note For seek mode tests the drive is placed in seek mo...

Page 18: ...l Storage can be extended to 1 year packaged or unpackaged under optimal environmental conditions 25 C 40 relative humidity non condensing and non corrosive environment During any storage period the d...

Page 19: ...is equipment generates and uses radio frequency energy and if not installed and used in strict accordance with the manufacturer s instructions may cause interference to radio and television reception...

Page 20: ...icals as electronic drive component reliability can be affected by the installation environment The silver copper nickel and gold films used in Seagate products are especially sensitive to the presenc...

Page 21: ...SATA interface connects point to point with the SATA host adapter There is no master slave relationship because each drive is considered a master in a point to point relationship If two drives are att...

Page 22: ...g dimensions Follow these important mounting precautions when mounting the drive Allow a minimum clearance of 0 030 inches 0 76mm around the entire perimeter of the drive for cooling Use only 6 32 UNC...

Page 23: ...Seagate BarraCuda Product Manual Rev D 22 www seagate com Configuring and Mounting the Drive Figure 3 Mounting dimensions 3 and 4 disk models...

Page 24: ...pply to the case of backplane blindmate connector only In this case the mating sequences are the ground pins P4 and P12 the pre charge power pins and the other ground pins the signal pins and the rest...

Page 25: ...estore B1H C0H Device Configuration Set B1H C3H Device Reset 08H Download Microcode 92H Execute Device Diagnostics 90H Flush Cache E7H Flush Cache Extended EAH Format Track 50H Identify Device ECH Idl...

Page 26: ...B0H D8H S M A R T Execute Offline B0H D4H S M A R T Read Attribute Thresholds B0H D1H S M A R T Read Data B0H D0H S M A R T Read Log Sector B0H D5H S M A R T Return Status B0H DAH S M A R T Save Attr...

Page 27: ...h Device requires SET FEATURES subcommand to spin up after power up and IDENTIFY DEVICE data is complete 8C73h Device does not require SET FEATURES subcommand to spin up after power up and IDENTIFY DE...

Page 28: ...9 Reserved 8 Multiple logical sector setting is valid 7 0 Current setting for number of logical sectors that shall be transferred per DRQ data block on READ WRITE Multiple commands 5C10H 60 61 Total...

Page 29: ...es enabled xxxxH 80 Major version number 07F0H 81 Minor version number 006DH 82 Command sets supported 306BH 83 Command sets supported 7561H 84 Command sets support extension see note following this t...

Page 30: ...or 0002H 169 205 ATA reserved 0000H 206 SCT Command Transport 10A5H 207 208 ATA reserved 0000H 209 Alignment of logical blocks within a physical block 4000H 210 216 ATA reserved 0000H 217 Nominal medi...

Page 31: ...A FUA EXT and WRITE MULTIPLE FUA EXT commands are supported 7 WRITE DMA QUEUED FUA EXT command is supported 8 64 bit World Wide Name is supported 9 10 Obsolete 11 12 Reserved for TLC 13 IDLE IMMEDIATE...

Page 32: ...nt register Sector Count register values 00H Set PIO mode to default PIO mode 2 01H Set PIO mode to default and disable IORDY PIO mode 2 08H PIO mode 0 09H PIO mode 1 0AH PIO mode 2 0BH PIO mode 3 0CH...

Page 33: ...that eliminates unnecessary drive returns The diagnostic software ships with all new drives and is also available at http seatools seagate com This drive is shipped with S M A R T features disabled U...

Page 34: ...ted States 408 658 1000 ASIA PACIFIC Seagate Singapore International Headquarters Pte Ltd 7000 Ang Mo Kio Avenue 5 Singapore 569877 65 6485 3888 EUROPE MIDDLE EAST AND AFRICA Seagate Technology SAS 16...

Reviews: