![Seagate Barracuda 18LP ST318275LC Product Manual Download Page 48](http://html1.mh-extra.com/html/seagate/barracuda-18lp-st318275lc/barracuda-18lp-st318275lc_product-manual_1222410048.webp)
38
Barracuda 18LP Product Manual, Rev. E
Forced air flow may be required to keep temperatures at or below the specified case temperatures of Table 3,
Column 2, in which case the drive should be oriented, or air flow directed, so that the least amount of air flow
resistance is created while providing air flow to the electronics and HDA. Also, the shortest possible path
between the air inlet and exit should be chosen to minimize the travel length of air heated by the drive and
other heat sources within the rack, cabinet, or drawer environment.
If forced air is determined to be necessary, possible air-flow patterns are shown in Figure 8. The air-flow pat-
terns are created by one or more fans, either forcing or drawing air as shown in the illustrations. Conduction,
convection, or other forced air-flow patterns are acceptable as long as the temperature measurement guide-
lines of Section 6.4.1 are met.
Figure 8.
Air flow (suggested)
Note. Air flows in the direction shown (front to back)
or in reverse direction (back to front)
Note. Air flows in the direction shown or
in reverse direction (side to side)
Above unit
Under unit
Above unit
Under unit
Summary of Contents for Barracuda 18LP ST318275LC
Page 1: ...Barracuda 18LP Family ST39175LW LC ST318275LW LC Product Manual Volume 1...
Page 2: ......
Page 3: ...Barracuda 18LP Family ST39175LW LC ST318275LW LC Product Manual Volume 1...
Page 6: ......
Page 10: ......
Page 12: ......
Page 16: ...6 Barracuda 18LP Product Manual Rev E Figure 2 Barracuda 18LP family drive...
Page 28: ......
Page 50: ......
Page 80: ......
Page 84: ......
Page 88: ......
Page 95: ......