1. 

Select cooling cycle rate 

 The 

FA

 setting is used to produce shorter cooling cycles.

 

The 

SL

 

setting produces a longer cooling cycle. Both settings produce very accurate 
temperature control and can be set to your personal preference.

 FA 

cycles the 

system at a 0.5ºF (0.5ºC) differential, and 

SL 

cycles the system at 1.5ºF (1.5ºC). 

 
2. 

Select heating cycle rate 

 

The 

FA

 setting is used to produce shorter heating cycles.

 

The 

SL

 

setting produces a longer heating cycle. Both settings produce very accurate 
temperature control and can be set to your personal preference.

 FA 

cycles the 

system at a 0.5ºF (0.5ºC) differential, and 

SL 

cycles the system at 1.5ºF (1.5ºC). 

 

3.

 

Select system heating type 

 

Users can select the system heating type according to their heating 

system. Select 

0

 for gas, oil, or electric heating systems. Select 

1

 for a heat pump 

heating system. 
 
4. 

Select display backlight

 

 

The display backlight improves display contrast in low lighting 

conditions. Select 

1

 for NO backlight display. Select 

2

 for the backlight to come on 

for approximately 30 seconds when any button of the thermostat is touched. 
Select 

3

 for the backlight to remain on continuously. 

NOTE: When operated from batteries only, the LCD display backlight will be 
illuminated less than 5 seconds after each button pressed ,when backlight option 
are set to 2) or 3). Options 2) & 3) will operate the same when terminal “C” is not 
connected. 

 
5. 

Select filter replacement run time

 

 

The thermostat will display the 

Filter Alarm 

after a set time of operation. 

This is a reminder to change or clean your air filter. This time can be set from 0 to 
12 months in 1 month increments. Selection of 

00

 WILL CANCEL THIS FEATURE. 

When 

Filter Alarm 

is displayed, you can clear it by pressing the 

 button for 3 

seconds (To enter filter program) and then hold the 

 and 

 buttons. This resets 

the timer and starts counting the days until the next filter change. 
 
6. 

Select ºF 

or 

ºC

 readout 

 

Changes the display readout to Centigrade or Fahrenheit as required. 

 
7. 

Select temperature recalibration 

 

This feature allows you to adjust the displayed room temperature up to 

4º higher or lower. Your thermostat can be accurately calibrated to match your 
previous thermostat. The current or adjusted room temperature will be displayed 
on the display. 
 
8. 

Select compressor lockout delay 

 

To protect the compressor from short cycling, you can select 

compressor off-time cycle between

 0

 or 

5

 minutes. When the thermostat 

compressor time delay occurs, the 

Cool On

 or 

Heat On

 display will flash during 

compressor lockout. 
 

-8- 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 4, Typical wiring diagram for heat/cool, 

4 wire, single transformer system 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Note* Jumper required in heat pump mode. 

 

Figure 5, Typical wiring diagram for heat pump 

with reversing valve 

 

CHECK THERMOSTAT OPERATION----------------------------------------------------------------------- 
 

If at any time during testing your system does not operate properly, contact a qualified 
service person. 
 
Turn on power to the system. 
 

Fan Operation 

Move the system switch to the 

OFF

 position. If your system does not have a “G” (Fan) 

terminal connection, skip to the Heating System. 
 

1. 

Move the fan switch to the 

ON

 position. The blower should begin to operate. 

2. 

Move the fan switch to the 

AUTO

  position. The blower should stop immediately. 

 
 
 
 

-5- 

Heating System 

950-0078-revI                                                                                                                                                                                                                                                                                  November 21, 2008 

Summary of Contents for TSN11X

Page 1: ... damages or implied warranties so the above limitations or exclusion may not apply to you INTERNATIONAL REFRIGERATION PRODUCTS CO INC Toms River N J 08755 Customer Service Phone 704 504 8590 Fax 704 504 3023 www irproducts biz 12 TSN11X SINGLE STAGE THERMOSTAT 1 Heat 1 Cool single stage thermostat Non Programmable Compatible with heat pump system Installation and Operation Manual Specification Pow...

Page 2: ...AY 15a 17 16 14 15 13 12 11 18 10 9 8 6 7 6 Filter Alarm Indicates filter needs to be replaced 7 Alarm This option available in Heat Pump models 8 Heat Cool Setting Indicates whether the current set point temperature is for Heating or Cooling 9 Displays the current Set point temperature 10 Indicates the thermostat is calling for heat in the heat pump mode 11 Battery Icon If the battery icon is bli...

Page 3: ...acement of the mounting holes 7 Move the base out of the way Drill mounting holes Use a hammer to tap in the supplied anchors into the mounting holes 8 Fasten the base loosely to the wall as shown in Figure 1 using two mounting screws Place a level against the bottom of the base and adjust until level then tighten the screws Leveling is for appearance only and will not affect thermostat operation ...

Page 4: ...maintain is shown on the right side of the display If you want to turn the system off just move the SYSTEM switch to the OFF position and the FAN switch to the AUTO position 2 Set current day and time Move the system switch to COOL or HEAT Press the button momentarily The hours display will begin to blink Press the or buttons until you reach the correct hour and AM PM designation AM begins at mid ...

Page 5: ...s is a reminder to change or clean your air filter This time can be set from 0 to 12 months in 1 month increments Selection of 00 WILL CANCEL THIS FEATURE When Filter Alarm is displayed you can clear it by pressing the button for 3 seconds To enter filter program and then hold the and buttons This resets the timer and starts counting the days until the next filter change 6 Select ºF or ºC readout ...

Page 6: ...usly display the temperature during a loss of AC power 1 Place the COOL OFF HEAT switch in the OFF position 2 Put the FAN AUTO ON switch in the AUTO position 3 Gently pull the cover straight off the base 4 Install two AAA alkaline batteries in the battery compartment Be sure to match the positive ends of the batteries with the positive terminals marked in the battery compartment 6 5 It may take as...