IMPORTANT:

This product is an accessory or part of a system. Always read and follow the manufacturer’s instructions for the 
equipment before connecting this product. Comply with all applicable codes and safety regulations. Failure to do so 
may result in damage, injury or death.

PRODUCT OVERVIEW

The SEA vehicle loop detector is compatible with most gate operators. The SEA may be used in Center, Safety and Exit 
loop positions. The display feature makes set-up easy by displaying the optimum sensitivity setting required to detect a 
vehicle positioned on the loop. Ten sensitivity settings allow for fine adjustment of detection level. A 
PULSE/PRESENSE switch allows configuration of output relay for presence or one second pulse on entry operation. 
Four frequency settings provide flexibility in preventing crosstalk in multi-loop applications.

Sistemi Elettronici

di Apertura Porte e Cancelli

International registered trademark n. 804888

®

English

SPECIFICATIONS

CAUTIONS AND WARNINGS

CE REQUIREMENT: Use Pre-formed loops with built-in surge suppression for CE compliance. 
Connect shield on lead in wire to earth ground.
CE REQUIREMENT: Use CE rated power supply for CE compliance providing suppression as 
specified by EN61000-4-5.
Not to be used in safety applications.
When more than one loop detector is used, set each one to a different frequency.
Refer to DIP switch diagram for frequency settings.

!

Sensitivity       

    10 levels, 0-9

Display

     

     Indicates optimum sensitivity level, 0-9 Diagnostic aid

Loop frequency      

     4 settings (low, med-low, med-hi, high)

Loop inductance      

    20...2000µH (Q factor > 5)

Grounded loop      

     Isolation transformer allows operation with poor quality loops

Automatic tuning      

     Detector tunes to loop on power-up and following frequency 

     count function

Environmental tracking      

     Automatic compensation

Surge protection 

     Loop circuitry protected by surge suppressors

Detect output 

     COM, NO and NC contacts

Power / loop fault indicator 

     Green LED

Detect / frequency count indicator 

     Red LED

ASB (Automatic Sensitivity Boost) 

     Increases sensitivity after initial detection to prevent dropout due to 

     high-bed vehicles

Relay operation 

     Presence or one-second pulse on entry

Power 

     12VDC...24VDC, 24VAC (see Cautions and Warnings)

Operating Current 

     18 mA

Operating temperature

      -40°C...82°C    0...95% relative humidity

Dimensions (L x W x H) 

     76mm   -   22mm   -   70mm

Weight 

     68 g

Connector 

     7 position male, 5mm ctrs.

Rev.00 - 03/2013

2

67411575

Summary of Contents for LOOP 23105158

Page 1: ...elli International registered trademark n 804888 English LOOP VEHICLE LOOP DETECTOR SEA S p A Zona industriale 64020 S ATTO Teramo ITALY Tel 39 0861 588341 r a Fax 39 0861 588344 www seateam com seacom seateam com Rev 00 03 2013 23105158 67411575 ...

Page 2: ...n wire to earth ground CE REQUIREMENT Use CE rated power supply for CE compliance providing suppression as specified by EN61000 4 5 Not to be used in safety applications When more than one loop detector is used set each one to a different frequency Refer to DIPswitch diagram for frequency settings Sensitivity 10 levels 0 9 Display Indicates optimum sensitivity level 0 9 Diagnostic aid Loop frequen...

Page 3: ...display for a minute or so to see this effect Change the frequency setting to prevent crosstalk Sensitivity setting The 10 position rotary switch allows for precise adjustment of detection level The sensitivity level increases from position 0 thru 9 with position 0 being the lowest sensitivity Typical applications require a setting of 3 or 4 The sensitivity display simplifies the installation proc...

Page 4: ...dium low off on Medium high on off High off off DIP switch position 2 ASB enabled on ASB off off DIP switch position 1 Pulse on Presence off Position 0 9 Sensitivity Low high Red LED Presence detected on No presence off Frequency count flashing Indicates sensitivity setting required to detect vehicle Green LED Normal operation on Shorted loop 1 fast flash Open loop 2 fast flashes Abrupt change 20 ...

Page 5: ...operly soldered and sealed against moisture 4 Observe display level indicated on display indicates residual frequency shift from vacant loop to vehicle presence press Frequency Count switch to reinitialize the detector Detector remains in detect after vehicle has left loop 1 Faulty loop 2 Poorly crimped terminals 3 Loose connections 1 Perform megger test from loop lead to ground should be 100 mego...

Page 6: ... to the road surface in appropriate grooves made using masonry cutting tools or the like Across cut at a 45 inclination must be made at the circuit angles so as to prevent the risk of the coil cable being damaged in proximity to the apex of the right angles Nominal groove length 4 mm Nominal groove depth 50 mm The coil detector connection cable must also be laid in an appropriate groove running fr...

Page 7: ...tten on the operator GOLD The mechanical components of the operators belonging to this line are guaranteed for 36 months from the date of manufacturing written on the operator PLATINUM The mechanical components of the operators belonging to this line are guaranteed for 36 months from the date of manufacturing written on the operator The base warranty 36 months will be extended for further 24 month...

Page 8: ...urity and efficiency if components used are not produced by SEAS p A 10 For maintenance strictly use original parts by SEA 11 Do not modify in any way the components of the automated system 12 The installer shall supply all information concerning system s manual functioning in case of emergency and shall hand over to the user the warnings handbook supplied with the product 13 Do not allow children...

Page 9: ...1996 including A1 2001 Conducted immunity Pass REF EN 55011 2007 Limits and methods of measurement COSTRUTTORE o RAPPRESENTANTE AUTORIZZATO MANUFACTURER orAUTHORISED REPRESENTATIVE SEAS p A DIREZIONE E STABILIMENTO Zona industriale 64020 S ATTOTeramo ITALY Tel 39 0861 588341 r a Fax 39 0861 588344 Http www seateam com I test sul prodotto sono stati effettuati in configurazione standard e in riferi...

Page 10: ...e highest quality levels and for your complete satisfaction Thanks for choosing SEA Este articulo ha sido producido siguiendo rigidos procedimientos de elaboracion y ha sido probando singolarmente a fin de garantizar los mas altos inveles de calidad y vuestra satisfaccion Le agradecemos por haber escogito SEA Cet article a été produit suivant des procédures d usinage strictes et il a singulièremen...

Page 11: ......

Page 12: ...ettronici di Apertura Porte e Cancelli International registered trademark n 804888 SEA S p A Zona industriale 64020 S ATTO Teramo ITALY Tel 39 0861 588341 r a Fax 39 0861 588344 www seateam com seacom seateam com ...

Reviews: