Controls, Indicators and Connections
Front
Back
POWER
LED
Green T-1 Glows when power is applied
DETECT
LED
3/4
Red T-1 Glows to indicated detection
FREQUENCY
COUNTER
Pull up toward Power LED and release
Momentary Switch
RESET
Momentary Switch
Push down toward Freq. and release
FREQUENCY Three position Switch
Low, High, Medium
Unit must be reset after any change!
SENSITIVITY BCD Switch
0,1,2,3,4,5,6,7,8,9 must be on a number
DIP SWITCH FUNCTIONS
DIP switch
OFF ON
1 Pulse on relay 2 Presence on relay 2
2
8
Pulse on Detect
Pulse on Un-detect
Costant presence
3
4 minute limited
presence time
“Fail Secure”
“Fail Safe”
4
5 Filter OFF Filter ON
ASB OFF
Automatic Sensitivity
Boost
6
Extended Detect
6 seconds
7
3 seconds
DIP 7 & 8 ON Extend time is 9 seconds
For more details see page 9 and 10.
Extended Detect
CONNECTIONS
PIN FUNCTION
1 POWER +
2 POWER -
3
RELAY 2 N/O
(IPUSE OR PRESENCE)
4* GROUND*
5 PRESENCE RELAY (1) COM
6** PRESENCE RELAY (1) N/O
7 LOOP
8 LOOP
RELAY 2 COM
(PULSE OR PRESENCE)
9
10** PRESENCE RELAY (1) N/C
RELAY 2 N/C
(PULSE OR PRESENCE)
11
* NOTA
: Pin 4 must be connected to earth ground
for surge protection to be effective.
**NOTE
: Functions on pins 6 and 10 are reserved
if DIP switch 4 is set to OFF “Fail Secure”
operation.
English