IMPORTANT SAFETY INFORMATION

Clean and grease parts in movement (wheels, counter-connecting rod, release, etc.)
Check for corroded parts and replace if necessary
Check if the screws and all mounting hardwares are properly tighten
Check the conditions of wear and tear of the devices in movement
Check the correct drain of the rainwater
Check the integrity of the connection cables
Inspect the track for any signs of cracking or separation
Ensure that the gate moves freely

Y

EARLY

Y

EARLY

Y

EARLY

Y

EARLY

Y

EARLY

Y

EARLY

Y

EARLY

Y

EARLY

Check and confirm the proper operation of all safety devices (photocells, edge sensors etc)
Check and confirm the operation of all installed accessories 
Check and confirm the operation of the manual release

Check the battery conditions and be sure that connections are free of corrosion
Verify the functionally of the battery backup, or power failure option

GENERAL SAFETY PRECAUTIONS

The following precautions are an integral and essential part of the product and must be supplied to the user;

Read them carefully as they contain important indications for the safe installation, use and maintenance.

1.

 These instruction must be kept and forwarded to all possible future users of the system.

2.

 This product must be used only for that which it has been expressly designed.

3.

 Any other use is to be considered improper and therefore dangerous.

4.

 The manufacturer cannot be held responsible for possible damage caused by improper or unreasonable use.

5.

 Avoid operating in the proximity of the hinges or moving mechanical parts.

6.

 Do not enter the path of the moving gate while in motion.

7. 

Do not obstruct the motion of the gate as this may cause a situation of danger.

8.

 Do not allow children to play or stay within the path of the moving gate.

9.

 Keep remote control or any other control devices out of the reach of children, in order to avoid possible involuntary  

activation of the gate operator.

10.

 In case of break down or malfunctioning of the product, disconnect from the main power source. Do not attempt to 

repair or intervene directly, contact only qualified personnel for repair.

11.

 Failure to comply with the above may create a situation of danger.

12.

 All cleaning, maintenance or repair work must be carried out by qualified personnel.

13.

 In order to guarantee that the system works efficiently and correctly it is important to have the manufacturer's 

instructions on maintenance of the gate and operator carried out by qualified personnel.

14.

 In particular, regular checks are recommended in order to verify that the safety devices are operating correctly.

All installation, maintenance and repair work must be documented and made available to the user.

IMPORTANT SAFETY INSTRUCTIONS

        WARNING – T

O

 

REDUCE

 

THE

 

RISK

 

OF

 

INJURY

 

OR

 

DEATH

:

1.

 

R

EAD

 

AND

 

FOLLOW

 

ALL

 

INSTRUCTIONS

.

2.

 Never let children operate or play with gate controls. Keep the remote control away from children.

3.

 Always keep people and objects away from the gate. 

N

O

 

ONE

 

SHOULD

 

CROSS

 

THE

 

PATH

 

OF

 

THE

 

MOVING

 

GATE

.

4.

Test  the  gate  operator  monthly. The  gate 

MUST

  reverse  on  contact  with  a  rigid  object  or  stop  when  an  object 

activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to 
adjust and retest the gate operator properly can increase the risk of injury or death.

5.

 Use the emergency release only when the gate is not moving

6.

 

K

EEP

 

GATES

 

PROPERLY

 

MAINTAINED

.

 Read the owner’s manual. Have a qualified service person make repairs to 

gate hardware.

7. 

The entrance is for vehicles only. 

P

EDESTRIANS

 

MUST

 

USE

 

SEPARATE

 

ENTRANCE

.

8.

  Every  gate  operator  installation 

MUST

  have  secondary  protection  devices  agains  entrapments,  such  as  edge 

sensors and photo beams more in particulary in places where the risk of entrapments is more likely to occur 

9.

 

S

AVE

 

THESE

 

INSTRUCTIONS

PERIODIC MAINTENANCE

TURNING OFF THE POWER

BY MAIN SOURCE TURNED-OFF

TURNING ON THE POWER

!

Y

EARLY

Y

EARLY

Y

EARLY

Y

EARLY

Y

EARLY

A

LL

 

THE

 

ABOVE

 

DESCRIBED

 

OPERATIONS

 

MUST

 

BE

 

MADE

 

EXCLUSIVELY

 

BY

 

AN

 

AUTHORIZED

 

INSTALLER

Summary of Contents for JOINT

Page 1: ...UPER FULL TANK 20 40 HYDRAULIC OPERATOR FOR SWING GATE REV 03 11 2020 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Toll Free 800 689 4716 www sea usa com 67411857 ...

Page 2: ...operator 10 In case of break down or malfunctioning of the product disconnect from the main power source Do not attempt to repair or intervene directly contact only qualified personnel for repair 11 Failure to comply with the above may create a situation of danger 12 All cleaning maintenance or repair work must be carried out by qualified personnel 13 In order to guarantee that the system works ef...

Page 3: ...d where applicable IMPORTANT INSTALLATION INSTRUCTIONS 1 Install the gate operator only when a The operator is appropriate for the construction of the gate and the usage Class of the gate b All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet 1 22 m above the ground to prevent a 2 1 4 inch 57 2 mm diameter sphere from passing through th...

Page 4: ...uction SEA USA Inc can not be deemed responsible for any damage or accident caused by product breaking being damages or accidents due to a failure to comply with the instructions herein The guarantee will be void and the manufacturer responsibility will be nullified if SEAUSAInc original spare parts are not being used The electrical installation shall be carried out by a professional technician wh...

Page 5: ...placement of external devices but they give only examples of suggested entrapment protection in their installation manuals If the installer identifies a risk of entrapment or obstruction at least two independent means of entrapment protection are required 4 TERMINOLOGY CHANGE The terms primary and secondary have been removed in the description of entrapment protection devices This was done to emph...

Page 6: ... the factory for instructions and authorization Merchandise returned for credit must becurrent uninstalledandunusedandreturnedinitsoriginalpackaging Freightmustbepre paidonallauthorizedreturns REPAIRS Repairsandpartsaresubject totheavailability instock Shipmentofproducts forrepairs must bepre paidbythecustomer Products shippedwithoutauthorization sender sdetailsanddescriptionoftheproblemswillberef...

Page 7: ...se of the electric lock on operators without block SB moreover the exclusion of electronic slowdown is recommended in case of operators with hydraulic slowdown 5 Cylinder 6 Electric motor 7 Hydraulic pump 8 Electric cable 29 53 ft 70 40 Fig 2 SUPER FULL TANK 20 G6 380V SFT 20 G6 380V SUPER FULL TANK 20 G6 120V SFT 20 G6 120V Fig 1 19 69 39 37 4 33 2 64 61 81 100 79 60 04 100 55 SUPER FULL TANK 40 ...

Page 8: ...rent Stroke Shaft speed Cycles per hour at 68 F Max working pressure Operating temperatures Thermal protection Max Thrust Capacitor Weight rotection class P Max leaf lenght Opening degree of the leaf SUPER FULL TANK 20 G6 380V SUPER FULL TANK 20 G6 120V TECHNICAL FEATURES SUPER FULL TANK 40 G4 120V The frequency of use is valid only for the first working hour and at 68 F temperature If operator wo...

Page 9: ...8 7 28 6 69 7 09 6 50 6 30 6 69 5 91 5 51 5 12 3 15 4 72 3 35 4 92 3 94 5 51 5 71 4 72 6 30 4 92 6 50 6 69 5 51 7 09 7 48 7 87 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 6 18 16 93 16 93 17 32 17 72 17 72 18 50 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 18 90 inches inches inches inches SUPER FULL TANK 20 SUPER FULL TAN...

Page 10: ...loose the parts listed in Fig 5 2 For a proper operation it is important to place as the operator as the front and rear brackets in a perfectly horizontal position with the help of a level as shown in Fig 10 Level REAR BRACKET INSTALLATION PRELIMINARY NOTES Fig 10 REAR BRACKET INSTALLATION The rear bracket must first be cut by respecting the a dimension shown on page 9 then welded Fig 13 The rear ...

Page 11: ...rocedure in Fig 34 and Fig 35 2 Pull out completely the chrome shaft then bring it back about 0 4 inches 3 Place the front bracket on the gate and place the shaft in the housing Fig 17 4 With the help of a level Fig 16 make sure that the operator is in a perfectly horizontal position then mark the front bracket position Fig 17 FRONT BRACKET INSTALLATION Level Fig 16 Fig 17 Fig 18 Fig 19 SCREWED FR...

Page 12: ...l the successive adjustments of the valves eg periodic maintenance should be made by unscrewing completely the external manual release see page 13 then make adjustments as shown in Fig 25 The opening and closing forces transmitted to the gate by the motor pump assembly are regulated by adjusting two by pass valves the grey valve adjusts the opening pressure while the yellow valve adjusts the closi...

Page 13: ...MENT The oil level should be measured with the shaft inserted into the operator The oil level must correspond to the level of the distributor surface OIL LEVEL Fig 31 Fig 33 Fig 32 DISTRIBUTOR LEVEL DISTRIBUTOR UNSCREW AND LIFT THE MANUAL RELEASE THREE PHASE CABLE CONNECTIONS 1 PHASE 1 U 2 PHASE 2 V 3 PHASE 3 W 4 MOTOR HEATING DETECTOR CONTACT NC 5 MOTOR HEATING DETECTOR CONTACT NC 6 GROUND YELLOW...

Page 14: ... 2 Check the oil level the oil cap is under the manual release 3 Replace the hydraulic oil with the oil recommended by the producer 4 Check the function of the release 5 Check the function of the by pass valves 6 Check and grease the fixation pins 7 Check the integrity of the connecting cables 8 Check the function and the conditions of the mechanical stops in opening and closing where the mechanic...

Page 15: ...l be void and the manufacturer responsibility will be nullified if original spare parts are not being used SEA USA Inc The electrical installation shall be carried out by a professional technician who will release documentation as requested by the Laws in force Packaging materials such as plastic bags foam polystyrene nails etc must be kept out of children s reach as dangers may arise Internationa...

Page 16: ...SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Toll Free 800 689 4716 www sea usa com sales sea usa com ...

Reviews: