background image

ALPHA 200 STANDARD 
ALPHA 330 STANDARD 

DIMENSIONS (mm)

Fig. 1

Fig. 2

12

0

L

C

05

2

ALPHA 200 ALPHA 330

L

C (stroke)

960 mm

290 mm

1160 mm

400 mm

Alpha 200           Alpha 330

230V~ (±5%) 50/60 Hz

70W (24V) - 260W (230V)

1,2 A (24V) - 3 A (230V)

290 mm             400 mm

40 (24V) - 20 (230V)

-20°C    +55°C

  9 kg                    9,5 kg

 2,0 m                    3,3 m

  90° - 110°              90° - 120°

1,7 cm/s

  4 uF (230V)       6,3 uF (230V)

250 daN (24V) - 350 daN (230V)

IP44

 200 kg                300 kg

INSTALLATION MANUAL

The 

ALPHA 

is provided with a mechanical locking system that grants the operator locking in the opened and closed position 

avoiding any needs for electric locks and/or magnetic locks. The torque intensity and the anti-crushing safety are adjustable through 
the control board.

Key-locked that must be used only in case of emergency and/or power failure to manually operate the gate.

MAIN PARTS

ENGLISH

TECHNICAL FEATURES

Power Supply
Power
Absorbed current
Stroke
Cycle/hour
Operating temperature
Weight
Max leaf lenght
Opening angle
Speed
Capacitor
Thrust force
Protection class
Max leaf weight

1

   Back bracket

2

   Electric motor

3   

Endless screw

4

   Front bracket

5   

Aluminum shaft-cover

6   

Capacitor housing (230V version)

7

   Manual Releasing

     

1

1

2

2

3

3

4

4

7

7

5

5

6

6

Sistemi Elettronici

di Apertura Porte e Cancelli

International registered trademark n. 804888

®

REV 06 - 07/2010

67410590

Note

: The frequency of use is valid only for the first hour at 20°C room 

temperature.

11

Summary of Contents for ALPHA 200 STANDARD

Page 1: ...que intensity and the anti crushing safety are adjustable through the control board Key locked that must be used only in case of emergency and or power failure to manually operate the gate MAIN PARTS...

Page 2: ...kg Max Leaf Weight Max Leaf Length ALPHA electromechanical operators DIAGRAM FOR THE USE OF ALPHA 200 AND ALPHA 330 ALPHA 330 24V 230V ALPHA 200 24V 230V ALPHA 330 24V 230V Notice The operator must be...

Page 3: ...pening Limit Switch stop in closing Fig 6 Fig 7 ALPHA 200 STANDARD ALPHA 330 STANDARD 2 INSTALLATION OF THE OPERATORS 2 1 Fix the holed mounting plate to the post using screws as shown in Fig 6 The pl...

Page 4: ...80 190 190 150 170 200 170 160 160 220 160 Vedi Fig 10 A C Fig 9 60 m m M IN Fig 10 ALPHA 200 STANDARD ALPHA 330 STANDARD Opening angle During selection prefer the higher dimensions of A and B The abo...

Page 5: ...turn into the opposit direction screw it see Fig 12 and 13 Note After installation in opening leave minimum 15 mm of working stroke to avoid that the operator goes into mechanical lock if necessary in...

Page 6: ...E if it is not possible to attach the front bracket with the bolts weld it to the gate Fig 17 being careful to protect the shaft from welding waste ENGLISH Sistemi Elettronici di Apertura Porte e Canc...

Page 7: ...ongue from the shaft cover Fig 20 and mount it on the operator through the two tie rods without excessively tightening the two cover nuts Fig 21 Tie rod 1 Tie rod 2 Cover nuts Cover nuts Fig 19 Sistem...

Page 8: ...CE SEA s r l can not be deemed responsible for any damage or accident caused by product breaking being damages or accidents due to a failure to comply with the instructions herein The guarantee will b...

Page 9: ...wrong use of the product can cause sever damages to people 2 The max length of the power supply cable between control unit and motors is 10m use cables with 2 5 mm section Use wirings with double insu...

Page 10: ...the earth installation has been correctly made connect all the metallic parts of the closing doors gates etc and all the components of the installation provided with earth terminals Apply all the safe...

Reviews: