Series 09MK3 Ku-Band Technical Specifications
4009-91MK3 Installation Manual
13-1
13.
Series 09MK3 Ku-Band Technical Specifications
The specifications of your antenna system are below. For Naval Engineering level information on this subject, please refer to
Antenna Installation Guideline – Site Arrangement, document number 130040_A available on the Sea Tel Dealer Support Site.
13.1.
Antenna Reflector/Feed 4009
The antenna assembly is comprised of the Dish, feed assembly and LNB. A variety of LNBs could be used, refer to LNB
specification for the LNB that is provided with your system.:
Reflector Diameter
1.0 m (40.0 inch)
Reflector Type
Spun Aluminum axis symmetric D Ring focus
Feed
Center focus Cassegrain feed with integral 9GHz radar filter and
Cross-Pol OMT
Cross Pol Isolation:
On axis: > 35dB, Off axis: > 30dB within 1dB contour
Port to Port Isolation
> 35 dB typical
Polarization
Linear w/motorized skew adjustment
Polarization control
24 volt DC motor with pot feedback
Transmit frequency range
13.75-14.5 GHz Ku Band
Receive frequency range
10.70-12.75 GHz Ku Band
Antenna Gain
TX Gain
40.6 dBi at 14.25 GHz Typical
RX Gain
39.8 dBi at 12.5 GHz Typical
Antenna Efficiency
65 Percent typical minimum
Antenna G/T (30
°
elevation, clear sky)
17.9 dB/K at 12.5 GHz
In the Radome
(typical)
13.2.
TX Radio Package ( -91 systems)
SSPB (Block Up-Converter)
Codan 4908, 8 or 16 Watt Mini BUC
IF Input Frequency:
950-1700 MHz
L.O. Frequency:
12.80 GHz
RF Output Frequency:
13.75-14.5 GHz
Input Power
+20VDC to +60VDC
13.2.1.
Provides RJ45 TCP/IP LAN and USB Type-B serial connections. Converts FSK data to provide direct serial USB
and Telnet access, and HTML pages of BUCs via an inbuilt Web server. Pass-through inline connection with
the IF input eliminates additional cabling. Daisy-chain connection to 7551
OPTIONAL 7550 M&C Interface Unit
13.2.2.
Provides access to the M&C serial command set of the BUC via USB. May be used as a permanent
connection indoors or a temporary connection outdoors at the BUC. Pass-through inline connection with the
IF input eliminates additional cabling. Powered via USB port. Daisy-chain connection to 7551.
OPTIONAL 7552 FSK to USB M&C Interface Unit
13.3.
BUC Power Supply
AC Input
85-264 VAC, single phase
DC Voltage Output
48 VDC
Max Power Consumption
300 watts
Voltage output Connection
Multi-conductor
Summary of Contents for Cobham 4009-91 MK3
Page 3: ......
Page 8: ...4009 91MK3 Installation Manual Table of Contents viii This Page Intentionally Left Blank ...
Page 20: ...4009 91MK3 Installation Manual Site Survey 2 8 This Page Intentionally Left Blank ...
Page 34: ...4009 91MK3 Installation Manual Installation 3 14 This Page Intentionally Left Blank ...
Page 44: ......
Page 54: ...4009 91MK3 Installation Manual Setup Blockage Zones 8 2 This Page Intentionally Left Blank ...
Page 64: ...4009 91MK3 Installation Manual Quick Start Operation 10 6 This Page Intentionally Left Blank ...
Page 84: ...4009 91MK3 Installation Manual DRAWINGS 14 2 This Page Intentionally Left Blank ...
Page 89: ......
Page 90: ......
Page 91: ......
Page 105: ......
Page 113: ......
Page 114: ......