Se-Kure Controls SK-800KME Series Installation Instructions Download Page 2

AC Power Light

Will be lit when the SK-195 AC/DC
Power Supply is supplying power to
the Alarm Center.

Low Battery Light

Will )))flash((( when batteries
should be replaced.
Will )))flash((( if no batteries are
installed and the AC power is on.

Key Disarm Light

Will be lit when the Alarm Center is
Disarmed using the Key-Lock.

Keypad Disarm Light

Will be lit when the Alarm Center is
Disarmed using the Key-Lock.

Circuit “A” Light & 
Circuit “B” Light

Will be lit if a Termination
“End Plug” is not installed.
Will )))flash((( if an alarm has
been caused on that circuit.
Will not be lit when all 
sensors and the Termination
“End Plug” have been 
properly installed.

Keypad Program Light

Will be lit when the Alarm
Center is in the keypad 
programming mode and
ready to accept a new code.

2.

Installation:

The ME Jr. plus 2 Control Module has (2) circuits; one marked Circuit “A” and one marked
Circuit “B”. Any combination of up to (10) Splitters/Strips can be Daisy-Chained to the
Control Module as long as the total number from both circuits Does Not Exceed (10). If all
(10) Splitters/Strips are chained to a single circuit, an “End Plug” must be installed in the
other circuit. An “End Plug” must also be installed in the last splitter of each chain.

Special Note: Place the ME Jr. plus 2 in the Key Disarm Mode to install splitters and sen-
sors. The Key Disarm Mode prevents the unit from Automatically Arming after (4) minutes.

• After arranging display, connect Splitters/Strips together using the 6 ft. 

(SK-847) cables (provided with each splitter). 
If specific lenth cables is required: you may order them using Part No. 
(SK-847-x), where x = the length of the cable in feet.

• Connect an ME Jr. Sensor to a port on the Splitter/Strip and to the corresponding display product.

Selecting Sensors for Display Product: (Sensors are available in Straight (P/LE) & Coiled (PC/LE).

SK-809
Telephone Modular “End Plug”

SK-847-x 

(x = Cable Length in Feet)

Extension (Connects Alarm Module
to Splitters & Splitters to Splitters)

SK-902
1" x 1" Bug Sensor

SK-943
Tie Sensor

SK-961
Ant Sensor

Other Straight,

Coiled & 

Dual Sensors 

Are

Available.

Ask Your 

Customer Service

Representative 

For Details.

SK-904
1" x 2" Rectangular
Sensor

SK-927
Parallel Port Sensor

SK-953
collar Lasso Sensor

SK-955
Slim-Line Sensor

SK-968
Mini Phone Sensor

SK-990
Bendable Label
Sensor

)

)

)

SK-HORN

Remote Horn

SK-800KME

ME Jr. plus 2 Alarm Module

SK-80108ME

8 Port KE Strip

SK-807ME

8 Large Port KE Splitter Box

SK-195

AC/DC Power Supply

Summary of Contents for SK-800KME Series

Page 1: ...rmed position 3 Remove the battery door 4 Before installing batteries plug the SK 195 AC DC Power Supply into the Alarm Module jack marked Pwr Input as shown in Fig 2 5 Install 4 fresh C Cell Alkaline batteries following and polarity shown in Fig 3 VERY IMPORTANT When installing batteries always follow the polarity indicated on the battery holder 6 Close the door as shown in Fig 4 The horn will Do...

Page 2: ...led in the other circuit An End Plug must also be installed in the last splitter of each chain Special Note Place the ME Jr plus 2 in the Key Disarm Mode to install splitters and sen sors The Key Disarm Mode prevents the unit from Automatically Arming after 4 minutes After arranging display connect Splitters Strips together using the 6 ft SK 847 cables provided with each splitter If specific lenth...

Page 3: ...The Keypad System features a device called Auto Arm It is intended to automatic ally arm the system after 4 minutes Operation of the Keypad System When power is first applied to the device it will use the factory default code of 1 2 3 4 The user should change this code as soon as possible The system will accept the default code until a new one has been entered Always enter the key before entering ...

Page 4: ...rared Remote 1 Open the battery compartment door to reveal the dip switches on the side of the SK 800MEI Alarm Module as shown in Fig 6 2 Unscrew and open the SK 882 Infrared Remote It is fastened together with a small phillips head screw shown in Fig 7 3 Arrange the Dip Switches into any configuration to create your own encoded signal Make sure the Dip Switches match on the Alarm Module and the I...

Reviews: