+44 (0)1543 443060
www.secontrols.com
Installation Guide - Door Applications
1.
Ensure door is free and clear of
all obstructions and debris.
2.
Install the Supplied pivot
bracket set to the actuator.
3.
Off er actuator up to door with the
door and actuator fully closed. Take
measurement of the fi xing height
required for the actuator not to touch
the opening door when door opens/
closes.
4.
Power the actuator to the fully
open position.
5.
Mark up the distance from the
hinge to the actuator to allow
the door to be opened to the
required position.
6.
Ensure the installation location
allows for the actuator to open to
the maximum opening angle.
7.
Mark up the bracket holes in all
four positions.
8.
Drive the actuator fully closed
and allow the door to close, ensure
the opening doesn’t clash with the
actuator.
9.
Fix actuator using screws
suitable for the door
construction.
Please keep these operating instructions for future
reference and maintenance. Subject to technical
modifi cations. Diagram is not binding.
10.
Attach the slider bracket and
bracket retention cable to the door.
Cycle test the door open and closed
multiple times to ensure correct
operation.
11.
Installation is complete, if
required add fi nger entrapment
stickers to the door.