中文
EN
D
LCD PL
ATE AMPLIFIER
25
24
From the Overview screen, the following options can be executed with the Master Control rotary encoder:
-
Turn left or right
to adjust the output level (Figure 16). The output gain and the relative change in dB
are shown. The output level is always recalled and is not affected by any reset function.
-
Turn one step and push
to quickly mute or unmute the amplifier output.
-
Push (without turning)
to open the Active Preset Info screen and see both the active preset and
the delay currently defined (Figure 17). Clicking "
Back
" will return to the Overview screen.
Letters "
CA
" after the name of the preset indicate that the cardioid directivity function is enabled.
End-fire function is denoted as "
EF
" and normal radiation shows no additional letters.
-
Press and hold 3 seconds
to enter the MENU.
ACTIVE PRESET INFO
M F 3 A P : D e f a u l t C A
U S E R D E L A Y :
0 . 6 4 m s
> B A C K
Figure 17.
Active Presets View.
MENU
To enter the MENU of the amplifier,
press and hold
the Master Control rotary knob for 3 seconds. A menu
as shown in Figure 5 will appear on the screen.
MENU
> DSP Settings
System Settings
Exit
Figure 18.
Main Menu.
Two submenus can be accessed from this point:
-
DSP Settings: signal processing settings such as presets, filters, EQ, delay are configured here.
-
System Settings: power amplifier operation settings are configured here.
Clicking "
Exit
" will return to the Overview screen.
DSP SETTINGS
DSP Settings menu is shown in Figure 19.
DSP S e t t i n g s
Back
> Preset Libary
Highpass Filter
Lowpass Filter
Phase Inversion
EQ 1
EQ 2
EQ 3
EQ 4
EQ 5
Bypass User EQ
Delay
Reset User Params
Input Sensitivity
Exit
Figure 19.
DSP Settings menu.
DSP SETTINGS > PRESET LIBRARY
Preset Library menu allows to load and save DSP processing presets. These are divided in two basic types:
-
Factory presets: these are the default configurations for each SE AUDIOTECHNIK'S® speaker intended
to be used with your subwoofer, and contain the information about factory pre-defined filter and
limiter settings.
They are marked with an "
F
" letter at the right side of the preset. More details can be found in the
Factory Preset
subsection of this manual.
-
User presets: 8 custom configurations for the user to define, using the factory presets as starting point
and saving additional adjustments, as:
- User High-pass filter settings
- User Low-pass filter settings
- User EQ settings
- User Delay settings
- User Phase Inversion (Polarity) settings
They are marked with a "