B.  Install Lockcase

      Make sure the lock hand matches the door hand, use the following diagram to determine the hand of door.

LH
Left Hand

LHRB
Left Hand
Reverse Bevel

INSIDE OF DOOR

OUTSIDE OF DOOR

RH

Right Hand

RHRB

Right Hand 

Reverse Bevel

INSIDE OF DOOR

OUTSIDE OF DOOR

1.   Change latchbolt handing

      If the hand of the latchbolt doesn’t match the door hand, remove the fixing screw and pull the latchbolt out from
      lock case.  Turn the latchbolt 180 ° to change the handling.  Position latchbolt back, into case and fasten it. 

Instructions for changing lock hand:

Remove 

screw

Pull out and 

turn

2.   Change hand of lock

      For RH and RHRB, the catch screw will be on the lock case side.  For LH and LHRB, the catch screw will be on the    
      lock cover side.

SECURITY DOOR CONTROLS   ■   WWW.SDCSECURITY.COM

[t] 800.413.8783  ■  805.494.0622  ■  E-mail: [email protected]  ■  801 Avenida Acaso, Camarillo, CA  93012  ■  PO Box 3670, Camarillo, CA  93011

Summary of Contents for ZR7500 Series

Page 1: ...unction being installed 3 Mortise door edge according to measurements on installation template and drill proper holes for trim 4 Recess for face plate the dimension is L 8 1 32 x W 1 5 16 x D 7 32 Hei...

Page 2: ...he latchbolt doesn t match the door hand remove the fixing screw and pull the latchbolt out from lock case Turn the latchbolt 180 to change the handling Position latchbolt back into case and fasten it...

Page 3: ...door and position lever onto the spindle 3 Install inside spring cage onto the spindle with the arrow pointing in the direction of inside lever rotation 4 Install inside mounting plate onto spindle Ti...

Page 4: ...spindle into hub of lock case 2 Install outside lever assembly with mounting posts through door and position lever assembly onto the spindle 3 Install inside spring cage onto the spindle with the arro...

Page 5: ...actuator is factory set for a 1 8 door clearance If the clearance between the door and jamb is more or less than 1 8 then the following adjustment must be made refer to Fig 2 A Loosen the Allen screw...

Page 6: ...oor unlocked Common Indicates door secure Optional S Latch Locked Status SPDT 5 Amps 125VAC Optional L Latch Status Sensor SPDT 5 Amps 125VAC Voltage and current rating stamped on solenoid Ground scre...

Page 7: ...on will void UL listing and warranty 3 Inside lever is locked outside is free 3A Incorrect handing 3A Remove mortise lock and reverse hand 4 Latch position switch does not signal properly 4A Adjustmen...

Reviews: