background image

INSTALLATION INSTRUCTIONS IP100HK (Hager)

ELECTRIC LATCH RETRACTION DEVICE KIT

MODELS: 4501-RIM & 4501-SVR

P:\INSTALLATION INST\SWITCH KITS\INST-IP100HK.vsd     REV -

09-15    Page 1  

Any suggestions or comments to this instruction or 

product are welcome.  Please contact us through 

our website or email [email protected] 

Step 2

Carefully slide the assembly 
back out until the linkage  JUST
makes contact with the latch 
retraction rod.  Tighten set 
screws.

ELECTRICAL DATA

12VDC @ 700/110mA

RED (+)

BLK (-)

PATENT #8,851,530

NOTE Retro-Fitting Vertical Rod Devices:

Before retro-fitting an electric latch assembly into a vertical device, the following must be done 
to ensure proper alignment.  Disconnect the vertical rods from the device.  Install the electric 
latch assembly as shown above.  Once the ELR is properly installed energize it so that the 
push pad is dogged down, by doing so it will allow for proper alignment for the vertical rods.  
Finally reconnect the vertical rods to the device and make the proper adjusments.

801 Avenida Acaso, Camarillo, Ca. 93012  •   (805) 494-0622  •
www.sdcsecurity.com  •  E-mail: [email protected]

SET

SCREWS

TIGHTEN SET 

SCREWS TO 

LOCK DEVICE 

IN POSITION

Step 1

Slide the Electric Latch Retraction 
assembly into device and attach 
the linkage to the latch retraction 
rod (short linkage for standard,
long linkage for 4' device).

Short

Long

SET SCREW

IP100 LINKAGE

Retrofit Installation Note:

42" or 48" exit devices that have been modified to fit a 36" or 

smaller opening, may not have the required space to fit the standard E. L. R. assembly. Always 
verify the distance from the end of the touchpad to the end rail, and if necessary, consult with the 
factory for appropriate selection.