The 930 EntryCheck
™
accepts 12 to 24 Volts AC/DC. System current draw (maximum):
Standby: 10mA at 12/24 Volts
During Operation: 100 mA max
IMPORTANT:
The maximum output current allowed is ½ Amp. Check the specifications of your locking
device. Make sure that the locking device draws less than ½ Amp. For locking devices that draw more
current, a separate power supply is required. (See Appendix B)
Note:
If connecting DC, make the connections to the Red and Black wires instead of the Gray and
White wires (see Appendix A – Page 11). Make sure the polarity is correct.
INPUT REQUIREMENTS
OUTPUT CAPABILITIES
The 930 EntryCheck
™
provides one SPDT dry contact relay (rated at 2 Amps at 24 VAC). The relay can
be configured for one of the following options:
• Voltage Output – Fail Safe or Fail Secure Locking Device
• Dry Contact Output – Control a Gate Operator/Garage Door
Two auxiliary ¼ A grounding outputs are available to drive external relays. These can be configured for:
• CCTV/Light Controller or other – First key press triggers a 10 second output.
• Doorbell or other – Press the symbol to trigger a 1 second output.
OPERATING TEMPATURES
Operating temperatures can range from -40°C to +70°C (-40°F to 160°F).
P:\INSTALLATION INST\Access Control\INST-930.vsd 0505 Page 4