Astra 200 - Page 17
Entering System Programming
To enter System Programming:
1. Turn on ignition.
2. Within 5 seconds, press the valet switch 5 times.
· The siren will provide three chirps, indicating that you have entered Programming.
3. Press the valet switch the number times equal to the System Option you want to change.
· The siren will chirp each time the valet switch is pressed.
4. Within 5 seconds, press the transmitter button corresponding to the desired operating mode for
that System Option.
· The siren will chirp to indicate the setting.
1 chirp
=
Button 1
2 chirps
=
Button 2
3 chirps
=
Button 3
5. When you are finished, turn off the ignition to save the changes.
Default Reset
Following this procedure will set all Programmable System Options to factory default settings.
1. Enter System Programming.
2. Press Transmitter Button 3.
· The siren will chirp 6 times indicating that the reset signal was received.
· All Programmable System Options are now set to factory default settings.
· The Valet Mode is off.
3. Turn off ignition.
Programmable System Options
The following is a description of the programming options. Some program branches control more than one
option, and may require accessing a particular branch number twice in order to program all desired features.
1.
Horn Chirps with Arm & Disarm.
Selects one of two modes: Normal, Horn Chirps
Normal. When selected, the horn will honk only when the alarm is triggered.
Horn Chirps. When selected, the horn will provide the arm/disarmed trigger indications, allowing the siren
installation to be skipped.
2.
Arm Mode.
Selects one of two modes: Manual Arming or Passive Arming.
3.
Passive Door Locking.
Selects whether or not the system will automatically lock the doors during
Passive Arming.
4.
Ignition Controlled Locks/ Override Code Set.
This dual program branch sets Ignition Controlled
Locking and programs the optional Emergency Override Code. If Lock Only is selected, the doors will not
automatically unlock when the ignition is turned off.
Override Code Set. Changes the Emergency Override Code for a higher level of security (see page 7).
5.
Ignition Door Unlocking.
Selects whether or not the system automatically unlocks the doors when
the ignition is turned off. The Ignition Door Locking feature may be programmed to unlock all doors or
the driver’s door only. If driver’s door only is selected, the optional Passenger Unlock feature must be
connected. (
See Two Stage Door Lock Diagrams)
System Programming
Summary of Contents for Astra 200
Page 4: ......