RC8-CQC™ Installation Instructions
Supporting the Cisco Quad Camera and
Cisco SX80, Plus & Pro Codecs
TEST YOUR
SCTLink™
CABLE
We highly recommend using an Ethernet Network Tester/Analyzer alongside our provided PowerSniffer to confirm your
SCTLink™
wiring. Our PowerSniffer only tests conductor continuity and will not identify data integrity or capacity issues.
1.
Test and verify your CAT6 STP or FUTP
SCTLink™
cable for EIA568A/EIA568B.
The
SCTLink™
cable must be between 10m (minimum) and 100m (maximum) length.
2. Connect one end of the
SCTLink™
cable to the “
SCTLink™
” connection on the Head End module.
3. Connect the other end of your
SCTLink™
cable to the provided PowerSniffer.
4. Connect the WPS-48 power supply to the Head End module.
5. Connect the WPS-48 power supply to AC mains.
6. If the
SCTLink™
cable is properly terminated, it will display eight GREEN LEDs.
If you get any other result,
stop and re-terminate cable
.
7. Once your
SCTLink™
cable has been tested, please disconnect the WPS-48 power supply from the RC8-HE module,
and the PowerSniffer from the
SCTLink™
cable, before proceeding to install.
INSTALL THE EXTENSION KIT
Connect the camera-end cables:
1.
Connect the RCC-C014 HDMI cables between the Quad
Camera’s HDMI 1 & 2 connectors (angled end) and the
RC8-CE’s “HDMI 1” and “HDMI 2” ports.
2. Connect the RCC-C037-0.3M UTP cable between the
Quad Camera’s RJ45 Ethernet port (angled end) and the
RC8-CE’s Ethernet port.
3. Connect the PPC-018 power cable between the Quad
Camera’s power connector and the RC8-CE’s “+12VDC
Output” port.
Connect the codec-end cables:
4. Connect two 3ft RCC-H001 HDMI cables between
the codec’s HDMI camera inputs and the RC8-HE’s
corresponding “HDMI Out 1 A” and “HDMI Out 2 A” port.
5. Connect the 3ft RCC-H016 UTP control cable between
the codec’s RJ45 camera Ethernet port and the RC8-
HE’s “Ethernet 1”.
Connect and Initiate the Extended System:
6. Connect one end of your
SCTLink™
cable to the RC8-HE
module’s blue “
SCTLink™
” port.
7. Connect the other end of the
SCTLink™
cable to the
RC8-CE module’s blue “
SCTLink™
” port.
8. Connect the WPS-48 power supply to the RC8-HE.
TECH SUPPORT: 203-854-5701 • WWW.SOUNDCONTROL.NET • © SOUND CONTROL TECHNOLOGIES, INC
•
ALLOW UP TO TWO MINUTES FOR THE QUAD CAMERA SYSTEM TO INITIALIZE
•
Power Supply Specifications (AC-Mains Side):
Input Voltage: 100VAC to 240VAC 47Hz to 63Hz. Efficiency: 85% minimum.
Turn-on Surge: Less than 60 amperes for a duration less than 1mS. Power Factor: 0.9 minimum (where applicable). 48VDC
power supply uses 2.80 amperes AC maximum. All specifications subject to change without notice.
Installation Status
- Refer to our modules’ LEDs for installation status.
For assistance troubleshooting INACTIVE LED statuses, please contact Tech Support at 203-854-5701.
MODULE LED
LABEL
ACTIVE
STATUS
INACTIVE
STATUS
RC8-CE
OK LED 1 & 2
Blinking Green (~1 second interval)
Blinking or Solid Red
RC8-HE
OK LED 1 & 2
Blinking Green (~1 second interval)
Blinking or Solid Red
RC8-HE
LINK
LED Solid
Blue Solid
Red
or
Dormant
RC8-HE
HDCP
1
&
2
Blinking
Green
N/A
Cable Table
- Part numbers, descriptions and functions of all SCT cables provided for the RC8-CQC™.
This kit is also inclusive of
[1] RC-RKL™ Rack Shelf
.
CABLE
DESCRIPTION
FUNCTION
[2] RCC-C014
1’ Angled HDMI Cables
Video connection between Quad Camera and RC8-CE module.
RCC-C037-0.3M 1’ Angled UTP Cable
Control connection (Ethernet) between Quad Camera and RC8-CE module.
PPC-018
1’ Power Cable
Power connection between Quad Camera and RC8-CE module.
[2] RCC-H001
3’ HDMI Cables
Video connection between the codec and RC8-HE module.
RCC-H016
3’ UTP Cable
Control connection (Ethernet) between the codec and RC8-HE module.
Updated: 7/17/2020