pressing the “Set” button to advance the resistance 

limit.  This will turn the LEDs on or off as indicated in 

the table on the following page.

Do not press the “Set” switch for about seven

seconds.  The new limit will be saved and normal

operation will start.

Using the LEDs to Set the Resistance Alarm Level

Resistance 

(Ohms)

LED

1

2

3

4

5

6

7

8

9

10

12

14

16

18

20

Calibration

Equipment Required

For this test, the SCS Wrist Strap and Ground Wrist 

Strap and Ground Monitor should be disconnected from 

the monitored grounds.
Use the SCS 

CTE701

 Workstation Monitor Checker.  

Connect the ground input of the checker to the ground 

terminal of the Wrist Strap and Ground Monitor.  Set 

the checker to a proper resistance alarm level (see 

the CTE701 User Guide).  Connect the red tip of the 

checker to the ground monitoring terminal (i.e. G1, or 

G2).  Press the Fail button on the checker.  The red 

LED of the corresponding ground of the monitor should 

remain on.  Press the Pass button on the checker – the 

corresponding light on the monitor should be green.  

Repeat these steps for all enabled ground monitoring 

inputs.
The checker verifies the proper operation of dual wrist 

strap monitoring.  Connect a 3.5 mm test cable to both 

the checker and to the operator jack of the monitor.  At 

this point the monitor should indicate failure.  Depress 

the Pass button on the wrist strap section.  The monitor 

should indicate a good connection.  While pressing the 

Pass button, press body voltage “high.”  At this point the 

Wrist Strap LED would be blinking red.

Figure 3.  SCS CTE701 Workstation Monitor Checker

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

 TestEquipmentDepot.com 

Summary of Contents for TB-9029

Page 1: ...allows continuous monitoring for excessive voltage on each operator The Wrist Strap and Ground Monitor is available in one model Item Description 773 Wrist Strap and Ground Monitor with World Wide Power Adapter SCS offers the following accessories for the Wrist Strap and Ground Monitor Item Description 2368 Dual Conductor Fabric Adjustable Wristband 2360 Dual Conductor Coil Cord 5 2370 Dual Conduc...

Page 2: ...indicates the resistance limit without a voltage being generated on the person at the same time The green LED indicates a proper connection of the operator A green LED plus a blinking red LED will indicate if there is a body voltage generated the operator may still be connected properly The green LED is off when a dual conductor ground cord is not plugged into the jack Enabling and Disabling Audib...

Page 3: ...sistance alarm level see the CTE701 User Guide Connect the red tip of the checker to the ground monitoring terminal i e G1 or G2 Press the Fail button on the checker The red LED of the corresponding ground of the monitor should remain on Press the Pass button on the checker the corresponding light on the monitor should be green Repeat these steps for all enabled ground monitoring inputs The checke...

Page 4: ...o the identified locations Be sure to connect the monitoring inputs to different physical locations than those points used for their grounding Person Voltage and Resistance Monitor Plug the dual conductor ground cord of the wrist strap into the jack on the front of the unit If the wrist strap is worn properly a green LED will come on otherwise red LED will be on In order to provide good ground con...

Page 5: ...or in accordance with all applicable local and government regulations Notice To reduce the risks associated with property damage Monitor must be checked periodically to verify each monitor circuit is functioning correctly The SCS Wrist Strap and Ground Monitor requires a suitable ground to function properly Refer to the proper section of this User Guide for information on connecting to a suitable ...

Page 6: ...y SCS in writing this information represents SCS best knowledge and belief based upon information provided by third party suppliers to SCS Part or Component Name Hazardous Substances or Elements Pb Hg Cd CrVI PBB PBDE Termination in capacitor 0603 X O O O O O Solder in diode X O O O O O Finish in diode X O O O O O Terminations in PCBs X O O O O O Terminations in resistors 0603 X O O O O O Plating ...

Reviews: