Installation
Wire Attachment
The AC adapter should not be connected during the
wire attachment process. Attach 18 AWG wires to the
unit as described below. Strip vinyl insulation at each
end of the wires to approximately 1/3 in. (8 mm). Twist
the stranded wire on each end before inserting wire into
each connector location.
Attach ground wire to the GND connector on the back of
the unit. Insert a small blade screw driver into the orange
slot above. Push inward and insert the stripped wire fully
into the hole in the green connector. Hold wire fully in
and release the screw driver to allow the wire to catch.
If you are planning to use the Ground Man Plus Ground
Monitor output to the tool, attach wire to the Out
connector on back of unit. Insert the wire as described
above.
Attach the impedance monitor wire(s) to the chosen
ground line(s) G1, G2, G3 connector(s) on back of unit.
Insert the wire as described above.
AC/DC Adapter Connection
Connect the circular plug of the AC/DC Adapter into the
power jack on the back of the unit.
Mounting
Determine the mounting location of the Ground Man
Plus Ground Monitor. Attach the unit using one of the
following recommended methods:
• Screws
• SCS Dual Lock Fastener
Enabling or Disabling Monitoring of
Ground Lines
Sometimes not all three ground points in the tool need
to be monitored. This procedure will set up the number
of ground lines (G1, G2, G3) that will be used, so that
there is no need to put jumpers or shunts on the unused
ground monitoring inputs. The AC Adapter should not be
plugged in at this moment.
alarm so that it is not missed. The unit will respond to
either positive or negative voltage. The alarm is also
activated when the wrist band is worn too loosely and
the loop resistance level is exceeded. The red LED
indicates an over the resistance limit without a voltage
being generated on the person at the same time. The
green LED indicates proper connection of operator.
A green LED plus blinking red LED will indicate if there
is a body voltage generated; operator may still be
connected properly. The green LED is off when a dual
conductor ground cord is not plugged into the jack.
Enabling and Disabling Audible Alarm
The audible alarm can be enabled or disabled by
momentarily pressing a recessed miniature push-button
Set switch located on the back of the unit while the
monitor is powered on. Use a pin to press the switch.
Environmental Conditions
This equipment has been tested and found to be safe to
operate within these environmental conditions:
• This is not a warranty of equipment performance within
these conditions.
• Indoor use only
• Ingress Protection: IPX0
• Altitude: Up to 2,000 m
• Mains supply voltage fluctuations up to ± 10% of the
nominal voltage.
• Transient over voltages up to the levels of over voltage
category II.
• Temporary over voltages occurring on mains supply.
• Pollution degree 2.
• Temperature: Maximum 110°F / 43°C Minimum 50°F /
10°C
• Humidity: Maximum relative humidity 80% for
temperatures up to 31°C decreasing linearly to 50%
relative humidity at 40°C .
Specification
Figure 2. Rear view of Ground Man Plus Ground
Monitor.
Power
AC/DC Adapter
Universal 100 - 240VAC, 0.5A,
~50 - 60Hz
Output: 12VDC, 1.5A
General
Dimensions (approx) 2.4" W x 0.85" H x 2.6" D (61
mm W x 21 mm H x 66 mm D)
Weight (approx)
75g